Installation Guide

3. Make the Electrical Connections
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the junction box and blower to a properly grounded,
grounding-type duplex receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or
Residual Current Device (RCD). Do not remove the grounding pins from the plugs. Do not use
grounding adapters.
NOTICE: The blower and junction box are equipped with cords and plugs. A qualified electrician must
install a GFCI- or RCD-protected, 120 V, 15 A, grounded duplex outlet. No other load should be on this
circuit.
Install a duplex electrical outlet behind the bath, at least 1-1/2 (38 mm) above the subfloor, and
within reach of the 24 (610 mm) power cord.
Plug the blower and junction box into this outlet.
4. Complete the Installation
Test Run the Bath
Operate the heated surface user keypad to test the temperature settings.
Fill the bath to a level at least 4 (102 mm) above the top of the highest airjet.
Turn off the bath and let sit for five minutes. Check all bath piping connections for leaks. Check for
leakage along the front, sides, and back of the bath.
Turn on the blower and run for 5 minutes. Check for proper operation and function.
For additional information on bath and heated surface operation, see the Operating Instructions -
Heated Surface and Operating Instructions - Bath With Airjets sections.
Finish the Installation
Install water-resistant wallboard and all finished wall, deck, and floor materials.
Apply silicone sealant to seal all areas where the bath and finished wall or deck meet.
Install the faucet trim.
Clean-up After Installation
When cleaning up after installation, do not use abrasive cleansers, as they may scratch and dull the
bath surface. Use warm water and a liquid detergent to clean the surface of the bath.
Install a GFCI-protected
120 V, 15 A grounded outlet.
Bond in accordance
with applicable codes.
24" (610 mm)
Maximum Distance
Power
Supply
24" (610 mm)
Maximum Distance
Junction Box