user manual

l abc
Expander
Threshold
Ratio
10. determines the level below which gain reduction will take place, variable from 20dBu
down to -40dBu. Gain reduction BELOW a threshold level constitutes dynamic range EXPANSION.
The Gain Reduction light bar graph meter indicates in decibels by how much the signal is expanded at
any instant.
11. sets the degree of expansion applied below the threshold level, variable from 1:1 to 25:1. A
ratio of 1:1 corresponds to zero expansion : Signal In = Signal Out. Aratio of 10:1 indicates that when
the input signal, below the threshold, falls in level by 1dB, the output level will fall 10dB.
12. determines the time taken for the gain to return to normal after the signal comes back above
the threshold level, adjustable from 40 milliseconds to 2 seconds.
13. (Attack) is a switched control offering either automatic signal-monitored setting of Expander
attack time or a fixed value of 2 milliseconds.
14. is the output level control for the entire channel, Compressor, Expander and Limiter. The output
level light bar graph meter indicates OUTPUT level when the channel is switched in circuit. When
the channel is bypassed, the meter indicates INPUT level.
15. selects the expansion effect to be in or out.
16, sets the level above which the signal will be limited (compressed at a high 25:1 ratio),
adjustable from 0dBu to 20dBu.
17. selects peak clipping. Clipping totally eliminates transient peaks, effectively acting as a
limiter with an infinity:1 ratio and an instantaneous attack time. The Clipper threshold follows the
Limiter threshold as set.
18. switches mains power on or off.
Release
ATK
Gain
EXPIn
Limiter
Threshold
Clipper In
Power