Owner's Manual

4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Level
Drill with 1
1
/
4
" (3.2 cm), 1/8" (3 mm),
and 1/16" (1.6 mm) drill bits
Pencil
Wire stripper or utility knife
Pliers
Tape measure or ruler
Caulking gun and weatherproof caulking compound
Phillips screwdriver
Flat-blade screwdriver
Vent clamps
Jigsaw or keyhole saw
Metal snips
Parts needed
6" (15.2 cm) round metal vent system
Vent clamps/duct tape as required
For non-vented (recirculating) installations, you will need:
Recirculation Kit. See the “Assistance or Service” section
to order.
For vented installations, you will need:
1 wall or roof cap
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood assembly with LED lights already installed (1)
Hood insert assembly with blower/electronic box
4.5 x 13 mm truss-head wood screws (11)
4.2 x 8 mm screws (8)
4 x 15 mm screws (10)
3.5 x 9.5 T10 (2)
Mounting brackets (4)
TORX
®†
adapter screws T10 and T20
®
adapter (1)
6.4 x 18 mm washers (8)
4.2 x 12 mm plastic washers (8)
6" (15.2 cm) round damper (1)
Parts not supplied
Optional Accessories
For non-vented (Recirculating) installations:
1. Please see the Assistance or Service Section for the
recirculation kit part number information.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualied technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specied on the model/serial rating plate. The model/serial rating
plate is located inside the liner behind the lter on the left wall of
the range hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult your
cooktop/range manufacturer installation instructions before
making any cutouts.
This range hood is recommended for use with cooktops with a
maximum total rating of 65,000 BTUs or less.
Grounded electrical outlet is required. See the “Electrical
Requirements” section.
The range hood is factory set for vented installations through
the roof or wall. For non-vented (recirculating) installations
see “Non-Vented (recirculating) Installation Through the Soft/
Cabinet” in the “Prepare Location” section. Recirculation Kit is
available from your dealer or an authorized parts distributor. See
the “Assistance or Service” section to order.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
†TORX
®
and T20
®
are trademarks of Acument Intellectual Properties, Inc.