Instruction for Use

11
IMPORTANT: should you experience diculty in
turning the burners knobs, please contact the After
Sales Service for the replacement of the burner tap if
found to be faulty.
IMPORTANT: when gas cylinder is adopted, the gas
cylinder or gas container must be properly settled
(vertical orientation).
REPLACING THE INJECTORS (see the injector table
in the Safety instructions)
Remove grids (A)�
Extract burners (B)�
Using a socket spanner of the appropriate size unscrew
the injector (C), unscrew the injector to be replaced�
Replace it with the injector suitable for the new type
of gas�
Re-assemble the injector in (D)�
If you have a multiple crown burner use side spanner to
replace the injector (E)�
Before installing the hob, remember to ax the gas
calibration plate supplied with the injectors in such a
way that it covers the existing information relating to gas
calibration�
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted,
remove the knob and proceed as follows:
tighten screw to reduce the ame height (-);
loosen screw to increase the ame height (+)
The adjustment must be performed with the tap in
minimum gas setting position (small ame):
The primary air of the burners does not need to be
adjusted;
At this stage, light up the burners and turn the knobs
from max position to minimum position to check
ame stability�
Upon completion of adjustment, reseal using sealing wax
or an equivalent material�
POSITIONING THE PAN SUPPORTS AND WOK SUPPORT
Position the pan supports by inserting the rubber feets
located on the bottom of supports into the slots found on
the surface of the metal top�