5. Remove spring retainer from the cap by turning the spring
retainer counterclockwise. Locate the “LP” and “NAT”
position on the spring retainer. Turn over the spring retainer
so the “NAT” arrow is pointing toward the cap.
6. Tighten the gas pressure regulator cap by using a large at-
blade screwdriver, turning the regulator cap clockwise.
7. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
Natural Gas:
Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.6 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 1"
(2.5 cm) water column pressure above the manifold pressure
shown on the model/serial/rating plate.
Line pressure testing above 1/2 psi (3.5 kPa) gauge (14"
[35.6cm] WCP)
The range and its individual shut-off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psi (3.5 kPa).
Line pressure testing at 1/2 psi (3.5 kPa) gauge (14"
[35.6cm]WCP) orlower
The range must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
To Convert Surface Burners from Propane to
Natural Gas
1. If the burner grates are installed, remove them.
2. Remove burner cap.
3. Remove the burner base by rst removing (2) T-20 screws.
Burner
A. Burner cap
B. Screws
C. Burner base
4. Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orice spud in the nut driver while changing it.
Insert nut driver into the gas opening and press down onto
the gas orice spud and remove by turning the gas orice
spud counterclockwise and lifting out. Set gas orice spud
aside.
5. Replace with correct Natural gas orice spud. See the
“Natural Gas Orice Spud/Hood Chart.”
Use the following chart to nd the exact orice spud
placement.
Natural Gas Orice Spud/Hood Chart
Burner
Rating
Stamp Size Burner Style
5,000 BTUs 99 0.99 mm Small burner
15,000 BTUs 175 1.75 mm Medium burner
20,000 BTUs 203
78
2.03 mm
0.78 mm
Large burner – main
Large burner – simmer
NOTE: Refer to serial tag for more information on burner ratings
and locations.
Burner orice spud
6. Place Propane gas orice spuds in plastic parts bag for
future use and keep with package containing literature.
7. Replace the burner base and screws. Tighten screws only
until burner is snug to cooktop, do not over-tighten.
8. Replace burner cap.
9. Repeat steps 2 through 8 for the remaining burners.
Adjusting Simmer Low Setting on Surface Burners
for Natural Gas
1. Unplug range or disconnect power.
2. Using the square bit screwdriver, remove the surface burner
control knobs and bezels (Oven control knobs and griddle
control knobs do not have to be removed).
LP
NAT
LP
NAT
LP
NAT
LP
NAT
A
B
C
DE
A. Access cap
B. Metal seal
C. Gas pressure regulator
D. Spring retainer in LP
position
E. Spring retainer in NAT
position
A
C
B
A
B
A. Size stamp
B. Fuel type stamp (L or N)