Manual

Check connection polarity. Reverse polarity on any terminals will damage
unit and is not covered by warranty.
Verify the DC load consumption. The power consumed by the DC load
should be less than the PV panel generates.
8. Specifications
SC 1210 SC1210LD SC1220LD
Battery Voltage: 12 VDC
PV open circuit voltage (max): 26 VDC
Charge current (max): 10 A 10 A 20 A
Load current (max): 10 A 10 A 20 A
Surge Current (max) 35A for 1 min 35A for 1 min 40A for 1 min
Operational current: < 10 mA <10 mA <15 mA
Regulated battery voltage
Sealed type: 14.2 VDC
Flooded type: 14.6 VDC
Load disconnect voltage: N/A < 11.5 VDC < 11.5 VDC
Load re-connect voltage: N/A 12.6 VDC 12.6 VDC
Recommended wire size: # 12 AWG # 12 AWG # 10 AWG
Operating temperature - 40 C to 60 C
Dimensions (L x W x H) 4.1 x 4.1 x 1.3 in
Weight: 0.28 kg 0.32 kg 0.35kg