Owner manual

11
DMX Operation
DMX Addressing
Prior to hanging any instruments,
set the DMX address of each xture.
Push the tabs above or below the
number window to set the address.
(Valid addresses range from 001 to 512.)
The light above the address block will
illuminate if a DMX signal is present.
Tip: Power is not required to set
DMX addresses. Therefore, DMX
addresses can be set for each xture
prior to hanging.
Image 87 operates on 9 DMX addresses:
Lamps = 1-8, HO/Std = 9
Image 47 operates on 5 DMX addresses:
Lamps = 1-4, HO/Std = 5
The 9th address (5th address for Image 47) controls the HO/Std setting.
Dimmer level from 0%~50% operates all the lamps at HO mode. Dimmer
level from 50%~100% operates the lamps in the Std mode and the overall
light output of the xture drops by ½ f-stop.
For the sake of simplication, it is advisable to select address sequences
such as 10, 20, 30, 40 and so on.
IMPORTANT!
The dimmer board/light console should have its channel set to LINEAR light
output response. (LINEAR response is the default setting on most dimmer
boards.)