User Manual

4-6 2-output Settings ( )
4
Settings for Advanced Functions
4-35
- Digital Laser Sensor LV-N10 Series User's Manual -
Warning output mode
If output 2 is set to "ALrt" (warning output mode), output 2 turns on (or off if the output
condition is set to N.C.) when either of the following errors occur:
Correction error in DATUM1 or DATUM 2 mode
ErH
For error recovery procedures, see "Troubleshooting" (page 6-2).
Counter output mode
When output 2 is set to [Cnt (counter output mode)], detection which counts the
output-1 output (OFF J ON edge) up to 9999 and makes a comparative judgment
with the setting value is possible.
The following 3 types of counter functions are available.
* When the counter value reaches 9999 (maximum value), 9999 is held thereafter.
Refer to page 4-3 "2-Output Settings ( )" for setting methods.
Reference
Refer to page 4-3 "2-Output Settings ( )" for setting methods.
Display Function in brief
oUr1
(Over1)
Over counter 1
Turns ON at a value higher than the setting. The count con-
tinues until reset.
*
oUr2
(Over2)
Over counter 2
The output turns ON only when the value is the same as the
setting value. The count continues until reset.
*
Auto
(Auto)
Auto reset
Outputs one-shot when the value is the same as the setting
value. The count value is automatically reset. The one-shot
time (Shot) can be set within the range of 1 to 9999 (ms).
Default: 10 ms