3-3 Adjusting the Sensitivity
3
Basic Operation
3-14
- Digital Laser Sensor LV-N10 Series User's Manual -
This method automatically sets sensitivity using a moving workpiece.
Sensitivity can be easily set by passing a workpiece without shutting down operating
equipment.
1
While the workpiece passes through,
press and hold the [SET] button until
"SEt" flashes.
2
After the workpiece has completely
passed through, release the [SET] but-
ton.
Calibration is complete after the setting
value flashes momentarily, and then
stops (lights up).
• If detection is not stable after the setting operation, for example due to
vibration, press the button to adjust the setting value.
• When performing two-point calibration on channel 2 of the 2-output type,
set the channel switch to "2".
Full Auto Calibration
Reference
Setting
value
MAX
MIN
Time
Received
li
g
ht intensity
The setting value is determined
as the middle value between the
maximum and minimum light
intensity received values
obtained while holding down the
[SET] button.
1
2