User Manual

9
6-1. Response Time
Longer response times lead to more stable detection.
LR-TB2000/TB2000C
LR-TB2000CL
6-2. Output Logic
Select N.O. or N.C. for the output logic. For details, see "4 Detection Mode" (page 4).
6-3. Output Mode
Standard [Standard]
The output is activated according to the detecting distance. For details, see "4 Detection
Mode" (page 4).
Window [Window]
The output is activated according to the detecting distance. For details, see " 4-3.
Window Mode" (page 5).
Stability [Stability]
This function can be used to check whether there has been a decrease in the amount of
light received due to problems such as dirt on the detected surface.
z When the I/O selection is [Out1 + Out2]
Output is activated if the amount of light received falls below the threshold (fixed value)
during the observation period.
Example) Chart during DATUM mode
Error [Error]
Output is activated when an error occurs. When the error is cleared, the output is also
automatically reset. For causes of errors, see " Error Display" (page 10).
6-4. Timer
This function can be used to delay the timing with which the sensor output is switched.
Off delay [Off-delay]
On delay [On-delay]
One shot [One shot]
Detecting
distance
[mm]
Repetition Accuracy[mm] (Typical) (Under stable temperature)
White Paper (Reflectivity: 90%)
Response Time [ms]
1 10 25 100 1000
1000±3
2000 ±25 ±7 ±6 ±3 ±3
Detecting
distance
[mm]
Repetition Accuracy[mm] (Typical) (Under stable temperature)
Gray Paper (Reflectivity: 18%)
Response Time [ms]
1 10 25 100 1000
1000 ±26 ±7 ±6 ±3 ±3
2000 ±69 ±21 ±13 ±6 ±4
Detecting
distance
[mm]
Repetition Accuracy[mm] (Typical) (Under stable temperature)
White Paper (Reflectivity: 90%)
Response Time [ms]
2 20 50 200 2000
1000 ±10 ±5 ±3 ±3 ±3
2000 ±26 ±8 ±7 ±5 ±3
Detecting
distance
[mm]
Repetition Accuracy[mm] (Typical) (Under stable temperature)
Gray Paper (Reflectivity: 18%)
Response Time [ms]
2 20 50 200 2000
1000 ±26 ±9 ±6 ±3 ±3
2000 ±71 ±22 ±15 ±9 ±5
Detection Mode Observation Period
DATUM
Negative setting value < detected value
< positive setting value
Distance Detected value < setting value
Window
LOW-side setting value < detected value
< HIGH-side setting value
NEAR
FAR
Distance
Setting value
A
mount of
received light
(workpiece >
background)
Amount of
received light
threshold (fixed)
Stability
output
(N.O.)
5 cycles
1567