Trouble Probable Cause Remedy
Digital display not illuminated No Power. Check 120 volt power source
Power button has not been Press power button once to turn
depressed, on
Fan not operating (digital ROOM humidity level is not 3% or Raise SET humidity level if
display is illuminated) more below SET humidity level, desired
Reservoir is empty. Increase fan speed.
Fill humidifier with water
i Fan running continuously,
unit will not shut off
Float is obstructed.
SET humidity level is 65%.
ROOM humidity level has not
reached 1% or more above SET
humidity level.
Free float from obstruction
A SET humidity percentage
of 65% operates fan
continuously. Adjust SET
level between 25% - 60%.
Continue to run until desired
humidity level is achieved This
may take up to 48 hours initially
Poor evaporation of water. ° Check filter message "CF" is Change to a fresh new filter
flashing NOTE: Local water purity varies
° Mineral buildup on filter, from area to area.
Neither bottle emptying. ° Bottle cap plunger missing post in Check orientation of bottles
bottom of cabinet Reposition so that bottle cap
° Dirty filters plunger (stem) is depressed by
post in bottom of cabinet.
Change to fresh new filters
(42-29959)
Bottles continues to empty ° Air is entering water bottle. Check "E-Z-FHi Side-Caps" and
valve assembly caps to ensure
tightness
Check for leak in water bottle
Ensure gaskets for"E-Z-Fill Side-
Caps" are in place
Left bottle not emptying ° Right bottle contains water The humidifier is designed so that
right bottle empties first
Refill display "F" is on before ° Unit is not set up on a level Position unit level (Some carpet
bottles are empty surface. (Float will not sense water padding may allow unit to sit lower
at the front of the cabinet.) in the front than rear with the
additional weight of water bottles
in the front of the cabinet Install
caster pads under front casters
(see page 5)
Display blinks or fan moves slightly Normal No action required
when humidifier is plugged in.
Fan operating slower than speed Humidifier is in "Dry Out Mode" Humidifier automatically switches
registered on digital display, fan to (WHISPER) F1 when "F" is
flashing
Humidifier not shutting off dubng Filter not dry During "Dry Out Mode", the
"Dry Out Mode" humidifier will continue to run on
(WHISPER) F1 speed as required
for up to 2 hours.
Alternating "F" and room humidity Reservoir is empty. Fill humidifier with water
displayed
Alternating "CF" and room humidity Filter may be dirty Replace filter.
displayed
CAUTION: Use only EPA Registered Bacteriostat
Use of other water treatment products may damage the filter elements. Under no circumstances should you use
water treatment products designed for Roto belt or Ultrasonic humidifiers.
14