OWNER’S MANUAL MODEL NO. 625.347001 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. Reverse Osmosis Drinking Water System u Warranty u How To Install If you have questions when installing, operating or maintaining your reverse osmosis system, call this toll--free number... 1--800--426--9345 SAVE THIS MANUAL PRINTED IN U.S.A. u How It Works u Care Of u Repair Parts 1 Sears, Roebuck and Co., Hoffman Estates, IL 60179 U. S. A.
-- WARRANTY -FULL WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM (except filter cartridges and R. O. membrane) For one year from the date of purchase, when the Reverse Osmosis Drinking Water System is installed and maintained in accordance with our instructions, Sears will repair, free of charge, defects in material and workmanship, except filter cartridges and the R. O. membrane. TO OBTAIN WARRANTY SERVICE, SIMPLY CONTACT THE NEAREST SEARS SERVICE CENTER THROUGHOUT THE UNITED STATES.
-- TABLE OF CONTENTS -Where To Install the RO System . . . . . . . . Tools and Materials Needed . . . . . . . . . . . Installation Steps . . . . . . . . . . . . . . . . . . . . Cold Water Supply Saddle Valve . . . . . Drain Adapter . . . . . . . . . . . . . . . . . . . . . Faucet . . . . . . . . . . . . . . . . . . . . . . . . . . . . RO Assembly . . . . . . . . . . . . . . . . . . . . . . Storage Tank, Tubing Connections . . . . Installation Steps - continued Sanitizing, Pressure Test, Purging . . . .
-- WHERE TO INSTALL THE RO SYSTEM -The RO assembly and storage tank is designed for installation under the sink, usually in the kitchen or bathroom. The RO assembly mounts on a wall surface, or can lay on the cabinet floor next to the storage tank. Hanger washers and wood screws are included for cabinet wall mounting. The RO product water faucet installs on the sink, or on the countertop next to the sink (pages 6 and 7). safety guides on page 2.
-- STEP 1: INSTALL COLD WATER SUPPLY SADDLE VALVE -Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The fitting must provide a leak- tight connection to the RO 1/4” tubing (see FIG. 8, page 8). A typical connection, using the included saddle valve is shown in FIG.3 - A below. An optional connection, using standard plumbing fittings (not included), is shown in B.
-- STEP 2: INSTALL DRAIN ADAPTER -J Note: Running the drain tubing directly to a floor drain, sump, standpipe, laundry tub, etc., as shown on page 18, is preferred. However, if that is not possible or practical, the included drain adapter installs in the sink drain pipe, always above or ahead of the p- trap (FIG. 4). Be sure to comply with your local plumbing codes. Other drain pipe fittings, in addition to the adapter, may be needed. J The drain adapter fits 1-1/2” sink drain pipe.
-- STEP 3: INSTALL FAUCET (cont.)-B. ASSEMBLE FAUCET FIG. 6 1. If not already assembled, install the rubber washer, spacer, flat (or lock) washer and hex nut onto the threaded faucet stud. 2. Apply Teflon tape to the end of the faucet stud. Turn the tubing adapter with a blue collet onto the stud and hand tighten, then wrench 1/4 turn only. BE CAREFUL NOT TO CROSS THREAD. insert spout faucet & spout remove tubing piece 3. Wet the o-ring seals on the faucet spout.
-- STEP 5: INSTALL STORAGE TANK, MAKE REMAINING TUBING CONNECTIONS -1. CONNECT DRAIN TUBING, FAUCET TO DRAIN ADAPTER: Referring to FIG. 8, run the loose section (connected to faucet barb fitting) of black 3/8”tubing from the faucet to the drain adapter, with a black collet, installed on page 6. Cut this tubing as needed to route in as straight of a run as possible, without loops, dips, low spots or kinks. Cut the end of the tubing square. Then, push all the way into the fitting.
-- STEP 6: SANITIZING, PRESSURE TESTING & PURGING -SANITIZING 6. If needed to clean, flush the prefilter sump with fresh water. Then, fill with water to about 1”from the top. Add 1.0 ounce of chlorine (ordinary 5.25% household bleach ...Hilex, Clorox, etc.) and mix in the water. Do not add chlorine first. Concentrated, it will attack plastics. Sanitizing is recommended upon installation of the RO system, and after servicing inner parts.
-- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS -product water. Taste- free, odor- free, clean, high quality drinking water is available for use. PREFILTER Water from the cold supply pipe enters the RO assembly prefilter first (FIG. 8 and schematic below). FAUCET The sink or countertop faucet has a hand operated, spring- loaded closed lever to prevent the waste of drinking water. You can also keep the faucet open by pushing upward on the lever and locking it against the faucet spout.
-- CARE OF YOUR REVERSE OSMOSIS SYSTEM -To keep your reverse osmosis system operating and making high quality water, you must make sure supply water is always within the limits shown in the specifications. Good supply water helps to assure longer life from the RO membrane cartridge, prefilter and postfilter cartridges. However, each of these will wear out in time and need replacement. Note: The prefilter cartridge has light gray netting and end caps. The postfilter has blue. Do not interchange.
-- CARE OF YOUR REVERSE OSMOSIS SYSTEM -2. Press inward while turning the RO cap to the left (?) to remove from the bracket/membrane housing. 5. Inspect the o-ring and collet. Replace if worn, cut or otherwise damaged. Carefully replace into the drain port. 3. Use a pliers, or heavy wire made into a hook, to pull the RO cartridge from the housing. 6. Be sure the flow control is in the end of the tubing, then push all the way into the fitting.
-- CARE OF YOUR REVERSE OSMOSIS SYSTEM -AUTOMATIC SHUTOFF SERVICE TUBING CONNECTION (continued) If tubing is used, other than supplied with the system, be sure it is of high quality, exact size and roundness with a smooth surface. If the shutoff assembly requires service, be sure to reassemble parts exactly as shown in FIG. 12, and to reconnect tubing as shown on pages 10 and 16. To Disconnect Tubing: Push the collet inward and hold with a finger while pulling the tubing out. FIG.
-- CARE OF YOUR REVERSE OSMOSIS SYSTEM -REVERSE OSMOSIS SYSTEM CARE GUIDE MODEL NO. 625.347001 1. AT LEAST every 6 months, replace the prefilter and postfilter cartridges. Clean or replace the flow control and screen. 2. Replace the RO membrane cartridge when the percent rejection of total dissolved solids (TDS) is less than shown in the specifications (see B, below). If any of the following occur before the 6 months, replace as directed. A. Slow Making of Product Water: Replace the prefilter cartridge.
-- DIMENSIONS and SPECIFICATIONS -- 15” 16” STORAGE TANK 9”dia. 16” Metric Supply water pressure limits . . . . . . . . . . . . . . . . . . . . . . . . 40 --- 125 psi 280 --- 860 kPa Supply water temperature limits . . . . . . . . . . . . . . . . . . . . . 40 --- 100 ° F 5 --- 40° C Maximum total dissolved solids (TDS) . . . . . . . . . . . . . . . 2000 ppm Maximum water hardness @ 6.9 pH . . . . . . . . . . . . . . . . . 10 gpg Maximum iron, manganese, hydrogen sulfide . . . . . . . . .
-- REPAIR PARTS -Kenmore Reverse Osmosis Drinking Water System, Model No. 625.
-- REPAIR PARTS -Kenmore Reverse Osmosis Drinking Water System, Model No. 625.347001 Key No. Part Number 1 7205350 2 Key No. Part Number Faucet 23 7205326 Storage Tank 7207920 Adaptor, 7/16”-24 x 3/8”Tubing 24 7207938 Adaptor, 1/4”NPT x 3/8”Tubing 3 7185788 Screw, #10-12 x 5/8”(8 req.
-- REMOTE LOCATION FOR REVERSE OSMOSIS SYSTEM -REMOTE RO INSTALLATION (storage tank not shown) Possible remote locations for the RO nearby the kitchen or bathroom sink include; (1) a basement area underneath the sink, and (2) an adjacent room or closet. Longer lengths of tubing may be needed (see parts list on page 17). You can run the drain tubing directly to 1 of several suitable open drain points, as shown below, bypassing the faucet airgap and p---trap drain.
OWNER’S MANUAL MODEL NO. 625.347001 Reverse Osmosis Drinking Water System For the repair or replacement parts you need Call 7 am -- 7 pm, 7 days a week 1 -- 800 -- 366 -- PART (1 -- 800 -- 366 -- 7278) The model number of your reverse osmosis system is found on the rating decal. This decal is on the top of the bracket.