Use & Care Guide: Manual de Uso y Cuidado English / EFpafiol Models, Modelos: 407.52702 l
Package Contents .......... i................. iJ..i.._..2 Installing the Gravity Drain H0se.i ........i/10,11 installing the External Pump ................. 12,13 Using the Pump ........................................ 14 Care and Maintenance ............................ 15 Troubleshooting ..................................... 16117 Error Codes ............................................ 18 Product Specifications ........................ 18,19 Master Protection Agreements ..................
IMPORTANT CAUTIONS FOR USING YOUR DEHUMIDIFIER. TO reduce the risk of fire, electrical shock, injury, or damage to the dehumidifiers, these safety precautions must be followed: Safety • Do not place the power cord near a heater. , Do not use an electrical outlet near flammable or combustible materials such as gasoline, propane, paint thinners, etc. ° Do not disassemble or modify dehumidifier parts or components. It may cause electric shock and failure. • Plug in the power cord properly.
OBSERVE ALL LOCAL CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG. ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE A 1IS-VOLT 60Hz, AC ONLY, 15A FUSED AND PROPERLY GROUNDED ELECTRICAL SUPLLY IS REQUIRED. A time delay fuse or time delay circuit breaker is recommended. Use a dedicated circuit serving only this appliance. RECOMMENDEDGROUNDINGMETHOD For your personal safety, thisappiiance must be grounded.
Step 1: Remove the dehumidifier Bucket (Fig. 1) J ii i • i Step 2: Locate the carry handle. Remove the carry handle from bucket by slightly pulling one side of the handle bracket and lifting carry handle. (Fig. 2) Step 3: Remove protective tape. Push rear bucket tabs in and lift bucket cover. Remove pump, hoses, and hardware bag that contains the hose clamps, PUmP screws and drainagej0int. (Eig; 3): FRONT REAR CAUTION Please be careful whentakingout materials. Do notdamagethe float in the bucket.
• Prior to installation, remove the pump and accessories from the dehumidifier bucket (see page 5). CHOOSING THE PROPER LOCATION Use the dehumidifier: • Install the dehumidifier on a level floor strong enough to support the unit with a full bucket of water. • • • For best performance, allow at least 12-18 inches of airspace on all sides of the unit for good air circulation. • Keep all outside doors, windows and other openings closed when operating the dehumidifier.
Dehumidifier Power Cord. 10 ft. Pump Drain Hose 3ft.
(_,) (4) (5) (2) (3) POWER ONfOFF (1) Once the unit is plugged in, the POWER INDICATOR (10) will light UP. Pressing the Power button once will turn the unit ON and illuminate the digital display (9). The display will show the humidity level of the room in 5% increments down to 20%. Pressing the Power button again will turn the display OFF and the unit will cease operating.
OPTION 1: EMPTYING MANUALLY 1. Pull out the bucket, grasping the side handles. (Fig. 1) 2. Carry !he bucket by grasping the front corner of the bucket with one hand and the back Qfthe bucket with the other hand( Fig. 2) 3. Empty the bucket and replace the bucket in the dehumidifier. (Fig. 3) NOTE: Dehumidifier will not work when the BU'CKET FULL indicator light is on or without the bucket properly placed in position. (Fig. 2) (Fig.
Step 2: Open the drain connector door. (Fig. 6) i! (FIG.S) Step 3: Install and secure the draina le joint onto the drain connector. (Fig. 7) " Drainage Joint i i (FIG.7) Step 4: Place large hose clamp on the flat end of the dehumidifier drain hose, (Fig. 8) / s / _Y / / (FIG.
Step5::insert the drain hose onto the drainage joint so that it is fully seated. (Fig. 9) " _ri i il i (FIG. 9) Step 6: Secure hose by pushing large hose clamp towards the drainage joint. (Fig. 10) (FIG, 10) Step 7: Place bucket in the dehumidifier for operation. (Fig. 11) (FIG.
OPTION 3: EXTERNAL VERTICAL PUMP INSTALLING THE EXTERNAL PUMP Step 1: To install Dehumidifier Drain Hose, refer to Gravity Drain Using Dehumidifier Hose instructions starting on page 9. Step 2: For optimal operation, it is recommended that the pump is placed on a flat and level location, Attach the water pump to a wall or other perpendicular flat surface with the included screws for security. (Fig. 12) (FIG. 12) Step 3: Remove red cap from drain hose connector on pump.
Step4: Insert pump drain hose onto pump connector until it is fully seated. (Fig. 14) i . J (FIG. 14) Step 5: Secure hose by pushing small clamp forward towards the pump. (Fig. 15) _-_ (FIG. t5) Step 6: Insert the angled end of the dehumidifierdrain hose into the water pump tank. (Fig. 16). (FIG.
NOTE: Make sure the drain hose is lower than the horizental plane of the drain on the dehumidifier as seen in the illustration below. Drain hose should be as short as possible and all kinks in the drain hose should be eliminated for proper pump operation. . 3ft. Dehumidifier Drain Hose X ili // (FIG. 17) NOTE: If you need to cut the dehumidifier drain hose, only cut on the flat end of the hose. Do not cut the angled end as it is designed for insertion into the pump.
CLEANING THE AIR FILTER After 250 hours of operation the FILTER RESET. indicator wilt light up to remind you to clean and change the air filter. It is recommended to periodically check the filter for excess dirt even if the FILTER RESET indicator is off. I. To remove the air filter, press the two filter tabs and pull the filter holder away from the back of the unit. 2. Remove the filter and clean with warm, soapy water. Rinse and allow the filter to dry before placing back in the unit. 3.
Problem Possible Causes Solutions ...... Dehumidifier does not start. r The dehumidifier is unplugged, Make sure the dehumidifier'spiug is I_ushed completely into the outlet. The fuse is blown I circuit breaker is tripped. Check the house fuse I circuit breaker box and replace fuse or reset breaker. Dehumidifier has reached the user set humidity level or the bucket is full. The dehumidifier automatically turns offwhen either condition occurs.
Pro 'em Possible Cau'ses Solutions ..,, .H Dehumidifier runs too much The area to be dehumidified is too large. The capacity of your dehumidifier may not be adequate for the room size. Doors and windows are open. Close all doors and windowsto the outside. , ,,,,,,,,,, Frost appears on the coils The dehumidifier has recently been turned on or the room temperature is below 41 °F, This is normal. Frost will usually disappear within 60 minutes.
Error Code Ft Possible Cause Error Type Ambient Temperature Sensor Malfunction I. Sudden Change in the surrounding temperature. Corrective Action 1. 2. 3. F2 Pipe Temperature Sensor Malfunction 2. Faulty Sensor 4. ITEM # Unplug the dehumidifier. Check the surrounding area for possible reasons for sudden temperature changes. Wait 30 minutes before plugging the dehumidifier back in for normal operation. If the "Error" is still indicated, please contactyour nearest service center.
Vertical Height Pumping 16 ft, Power Source 115 V ! 60 HZ Rated Current (Amps) , .t2A ,, ,,,,,,,,,, ,,,,,,,,,,,, .............. Dehumidifier Drain Hose Inside Diameter , .50 in. t 13 mm ,, ,,,,,,,,,,,, ,,,,,,,,, ,,,..................
Master Protection Agreements Congratulations on making a smart purchase. Your new Kenmore®product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance or repair from time to time. That's whenlhaving a Master Protection Agreement can save you money and aggravation. The Master Protection Agreement also helps extend the life of your new product.
SPANISH SECTION 21
SPANISH SECTION 22
SPANISH SECTION 23
Your Home For troubleshooting,productmanuals and expert advice: ,managemylife www.managemyltfe.com For repair- in your home - of all major brand appliances, lawn and garden equipment, or heating and coolingsystems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner's manuals that you need to dmit-yourseif. For Sears professionalinstallationof home appliances and items like garage door openers and water heaters. 1-800-4-MY-HOME -_ (1_00.