Installation Guide
GAS COOKTOP INSTALLATION INSTRUCTIONS
1
A
B
C
E
H
F
G
D
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
A01705102 (1410) Rev. A
English - pages 1-8
Español - páginas 9-18
Français - pages 17-28
If the information in this manual is not followed exactly, a fi re or explosion may result causing
property damage, personal injury or death.
FOR YOUR SAFETY:
— Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fi re department.
— Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
NOTE: Wiring diagrams for this cooktop are enclosed in this booklet
Printed in China
Figure 1
Gas Cooktop Dimensions
Gas Cooktop Cutout Dimensions
34"(86.4 cm)
Min
4"X 4" (10.2 cm x 10.2 cm)
opening to route gas supply.
Seal opening after routing
gas line.
For Standard
Installation:
1" (2.5 cm)
2"(5.1 cm)
7
1
/
4
"
(18.4 cm)
3"(7.6 cm)
2
¼
"
(5.7 cm)
All dimensions are stated in inches and (cm).
Do not slide unit into cabinet cutout.
Protruding screws on the bottom of unit
may damage the bottom front fi nish.
29
1
/
8
"
(74 cm)
**Note: D & E are critical to the proper
installation of the cooktop. D refl ects the
fi nished dimension. Due to the variation in
countertop materials, it is recommended
to fi rst undercut this dimension, and then
adjust it upon installation of the cooktop.
COOKTOP DIMENSIONS
CUTOUT DIMENSIONS
H. DEPTH BELOW
COOKTOP
LENGTH WIDTH
MODEL A. LENGTH B. WIDTH C. DEPTH D** E** F G
30 (76.2) 29
7
/8 (75.9) 25 (63.5) 7¾ (19.7) 29
15
/16 (76) 29
3
/16 (74.1) 22 (55.9) 1
1
/8 (2.9) Max. 7½ (19.1)
36 (91.4) 35
7
/8 (91.1) 25 (63.5) 7¾ (19.7) 35
15
/16 (91.3) 35
3
/16 (89.4) 22 (55.9) 1
1
/8 (2.9) Max. 7½ (19.1)
2"(5.1 cm) Dia.
Opening to route power
cable. Seal opening after
routing power cable.