Datasheet

12© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard T2073_T59X 3/6/2020
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
12
KEMET Organic Capacitor (KO-CAP
®
) – Automotive Grade
T591, T598, T597, and T599 High Humidity and High Temperature Automotive Grade Polymer Electrolytic, 2.5 - 50 VDC
Derating Guidelines
50%
55%
60%
65%
70%
75%
80%
85%
90%
95%
100%
55 25 45 85 105 125
Recommended Application Voltage V
R
16 V
Rated Voltage
Recommended Application Voltage V
R
10 V
67%
60%
54%
% Rated Voltage
Temperature (˚C)
67%
60%
54%
% Rated Voltage
Temperature (°C)
50%
55%
60%
65%
70%
75%
80%
85%
90%
95%
100%
55 25 45 85 105 125 150
Recommended Application Voltage V
R
16 V
Rated Voltage
Recommended Application Voltage V
R
10 V
125°C 150°C
Recommended Application Voltage
KO-CAPsaresolidstatecapacitorsthatdemonstratenowearoutmechanismwhenoperatedwithintheirrecommended
guidelines.WhiletheKO-CAPcanbeoperatedatfullratedvoltage,mostcircuitdesignersseekaminimumlevelof
assuranceinlongtermreliability,whichshouldbedemonstratedwithdata.Avoltagederatingcanprovidethedesiredlevel
ofdemonstratedreliabilitybasedonindustryacceptedaccelerationmodels.Sincemostapplicationsdorequirelongterm
reliability,KEMETrecommendsthatdesignersconsideravoltagederating,accordingthegraphabove,forthemaximum
steadystatevoltage.
Voltage
Rating
Maximum Recommended
Steady State Voltage
−55°Cto105°C 105°C to 125°C (T598) 105°C to 150°C (T599)
2.5V≤V
R
≤10V 90%ofV
R
60%ofV
R
60%ofV
R
V
R
≥16V 80%ofV
R
54%ofV
R
54%ofV
R
V
R
= Rated voltage