Datasheet

4© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard F3011_PME271M_X2_275 1/14/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Film Capacitors – AC Line EMI Suppression and RC Networks
PME271M, Metallized Impregnated Paper, Class X2, 275 VAC
Performance Characteristics
Rated Voltage 275 VAC 50/60 Hz
Capacitance Range 0.001 – 0.6 µF
Capacitance Tolerance ±20%, ±10%, ±5% on request
Temperature Range −40°C to +110°C
Climatic Category 40/110/56
Approvals ENEC, UL, cUL
Dissipation Factor
Maximum Values at +23°C
1 kHz 1.3%
Test Voltage Between Terminals
The 100% screening factory test is carried out at 2,150 VDC. The
voltage level is selected to meet the requirements in applicable
equipment standards. All electrical characteristics are checked
after the test. It is not permitted to repeat this test as there is a
risk to damage the capacitor. KEMET is not liable in such case
for any failures.
Insulation Resistance
Minimum Values Between Terminals
C≤0.33µF ≥12,000MΩ
C > 0.33 µF ≥4,000MΩ•µF
In DC Applications Recommendedvoltage≤630VDC
Environmental Test Data
Test IEC Publication Procedure
Endurance EN/IEC 60384–14
1.25 x V
R
VAC 50 Hz, once every hour increase to 1,000 VAC for 0.1
second, 1,000 hours at upper rated temperature
Vibration IEC 60068–2–6 Test Fc 3 directions at 2 hours each 10 – 55 Hz at 0.75 mm or 98 m/s
2
Bump IEC 60068–2–29 Test Eb 1,000 bumps at 390 m/s
2
Change of Temperature IEC 60068–2–14 Test Na Upper and lower rated temperature 5 cycles
Active Flammability IEC 60384–14 V
R
+20surgepulsesat2.5kV(pulseevery5seconds)
Passive Flammability IEC 60384–14 IEC603841,IEC6069511–5Needle-ametest
Damp Heat Steady State IEC 60068–2–78 Test Cab +4C and 93% RH, 56 days