Datasheet

3© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard F3116_C4AF 7/29/2020
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Power and AC Film Capacitors – Printed Circuit Board Mount Power Film Capacitors
C4AF, Radial, 2 or 4 Leads, 250 - 500 VAC, for Harsh Environment AC Filtering (Automotive Grade)
General Technical Data
Dielectric
Polypropylene metallized lm, non-inductive type,
self-healing property
Application
AC Filtering (250 VAC, 310 VAC, 350 VAC, 400 VAC, 500 VAC)
250 VAC rating reccomended ONLY for controlled output ltering
Special Features AEC-Q200 qualied
Climatic Category 55/105/56 IEC 60068-1
Maximum Operating Temperature 105 °C
Lower Operating Temperature –55°C
Standard IEC 61071, EN 61071, VDE0560, AEC-Q200
Protection
Solvent resistant plastic case UL 94 V-0 compliant
Thermosetting resin sealing UL 94 V-0 compliant
Installation Any position
Leads Tinned wires - standard lead wire length 6 (+0/−2) mm
Packaging Packed in cardboard trays with protection for the terminals
RoHS Compliance
Compliant with Directive 2002/95/EC and Directive 2011/65/EU of
the European Parliament and of the Council on 8 June 2011, including
Commission Delegated Directive (EU) 2015/863 amending Annex II to
Directive 2011/65/EU.
Electrical Characteristics
Rated Capacitance Range 1 to 62 µF
Rated Voltage (VNAC) Range 250 to 500 VAC (50/60 Hz)
Capacitance Tolerance ±5% (J) or ±10% (K) measured at T = +25°C ±5°C
Dissipation Factor PP
Maximum (tgδ0)
≤ 0.0007 with T = 25°C ±5°C
Surge Voltage 1.5 * V
NDC
for maximum 10 times in lifetime at T = 25°C ±5°C
Overvoltage (IEC 61071)
1.15 * V
NDC
for maximum 30 minutes, once per day
1.3 * V
NDC
for maximum 1 minute, once per day
Peak Non-Repetitive Current 1.5 * I
PKR
, for maximum 1,000 times in lifetime
Insulation Resistance IR x C ≥ 30,000 seconds at 100 VDC 1 minute at T = +25°C, ±5°C
Capacitance Deviation in the
operating temperature range
−55 to 105°C
±2.5% maximum on capacitance value measured at T = +25°C, ±5°C
Temperature Storage –40 to +80°C
Storage time ≤ 36 months from the date marked on the label glued to the package
Permissible Relative
Humidity - Storage
Annual average ≤ 70%, 85% on 30 days/year randomly distributed
throughout year. Dewing not admissible.