User Manual

Gain
Multiplies incoming values by the specified amount. Defaults to 1.00.
Offset
Adds the specified amount to incoming values. Use negative numbers for subtraction. Defaults
to 0.
Result
(Hosted mode only)
A live display of the modline values after passing through the gain and offset stage.
Table
Sets the type of curve to apply to the incoming values. Also used for toggle behavior and
interacting with the key counter. For a complete list of all available tables (and what they do)
see the Tables section of the Appendix.
Min
Sets the minimum value that can be output. All values below the minimum will be clipped to
this value — they are not ignored.
Max
Sets the maximum value that can be output. All values above the maximum will be clipped to
this value — they are not ignored.
Smooth
Adds smoothing to the data.
Sets the amount of time (in milliseconds) it takes to slide/interpolate to the next value. Smaller
values can smooth out jumpy data, while larger values can create longer ramps between
values.
Range: 0 - 5000ms
Delay
(Hosted mode only)
Applies a delay to the data.
Sets the amount of time (in milliseconds) to delay the incoming values.
Range: 0 - 5000
Value
(Hosted mode only)
A live display of the modline values after passing through the data modifiers section.
Advanced Editor 37