Only use splitters without diodes (EBC110 or EBC114). The required
diode protection is provided by outlets from the ESU series.
It is especially important to make sure that each userband is assigned only
once, since otherwise the receivers will generate mutual interference. The
frequencies are allocated on the receivers settings menu. Depending on the
type, this may be performed manually or automatically.
It is recommended that the wall sockets with the shorter length connec-
tions are assigned to the higher frequencies. By denition the system is
designed so that single-cable units are supplied with 14VDC. The power
supply is briey switched to 18VDC if control signals similar to DiSEqC™
have to be transmitted. Continuous application of 18V would block the
system. For this reason we recommend the use of ESU series outlets,
which are equipped for switching off
electronically.
The receivers that are connected must be designed for single-cable opera-
tion conforming to EN50494. In order to use userband 9, the receiver must
also support the single-cable standard SCD2 as per EN50607.