User manual
5 / 8
Only use splitters without diodes (EBC110 or EBC114). The required
diode protection is provided by outlets from the ESU series.
It is especially important to make sure that each userband is assigned only
once, since otherwise the receivers will generate mutual interference. The
frequencies are allocated on the receivers settings menu. Depending on the
type, this may be performed manually or automatically.
It is recommended that the wall sockets with the shorter length connec-
tions are assigned to the higher frequencies. By denition the system is
designed so that single-cable units are supplied with 14VDC. The power
supply is briey switched to 18VDC if control signals similar to DiSEqC™
have to be transmitted. Continuous application of 18V would block the
system. For this reason we recommend the use of ESU series outlets,
which are equipped for switching off
electronically.
The receivers that are connected must be designed for single-cable opera-
tion conforming to EN50494. In order to use userband 9, the receiver must
also support the single-cable standard SCD2 as per EN50607.