Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Voting Time (all
other tag types)
[ms]
From the Channel tab
on the Configuration
page:
Type the Voting Time
for all other tag types
in the appropriate
fields.
user with
Advanced
User
permissions
VOTETO
100
0-9999
Specify the time after the
initial entry of the
transponder into the
capture zone, subject to
the Programming
Timeout parameter.
Used by all
protocols
Dynamic Voting
Control
From the Channel tab
on the Configuration
page:
Select Disabled or
Reader from the
Dynamic voting
control drop-down
box (LC Speed and LC
Ends are not
supported).
user with
Advanced
User
permissions
DVCTRL
Disabled
Disabled
Reader
LC Speed
LC End
Disabled: no voting
control
Reader: the Reader
monitors the average
time an OBU is in the
capture zone and uses
this time to determine
an appropriate voting
time
LC Speed: not currently
supported
LC End: not currently
supported
to set type of
voting control