Installation Guide

IMPORTANT SAFEGUARDS:
When using electrical equipment, always adhere to basic safety precautions including the following:
SAVE THESE INSTRUCTIONS
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com
© 2011 Juno Lighting LLC Rev 3/12 P3217 pg 1 of 2
INSTALLATION INSTRUCTIONS
PRO-SERIES LED DIMMABLE UNDERCABINET LIGHTING
For use with 120V, 60Hz electrical power supply only.
WARNING: TO PREVENT OVERHEATING AND ELECTRICAL SHOCK DO NOT INSTALL IN SMALL ENCLOSED
SPACES. TO PREVENT ELECTRICAL SHOCK DO NOT INSTALL IN WET ENVIRONMENTS.
1. Read all of these instructions before
installing fixture.
2. Keep these instructions in a safe place for
future reference.
3. Only qualified electricians in accordance
with local codes should perform all
installations.
4. WARNING: For hard wire installation
(NM & BX) make sure electrical power
supply for installation circuit is shut
down at electrical service panel before
starting installation. Do not re-energize
circuit until installation is fully
completed.
5. Fixture is designed to be electrically
grounded for hard wire (NM & BX)
installations. WARNING: To prevent
shock closely follow grounding
directions.
2. Push NM supply cable through rectangular
wire grip in plate so outer jacket of cable
projects about 3/4" through plate.
3. Inside fixture are three wires with PUSH-IN
WIRE CONNECTORS fitted to each end.
Carefully pull these out of fixture. Do not
pull with excessive force.
4. Using strip length guide on PUSH-IN
WIRE CONNECTORS make sure lengths
of exposed wire on supply cable are correct.
5. Insert each of the three wires from the NM
supply cable into each of the three PUSH-
IN WIRE CONNECTORS with respective
color wires. Black to black, white to white,
and green (or bare copper wire) to green.
Make sure that feed wires are securely
gripped by the PUSH-IN WIRE
CONNECTORS and that with the exception
of a bare ground wire, none of the supply
wires show exposed wire where they enter
the PUSH-IN WIRE CONNECTORS.
6. Neatly push wires and PUSH-IN WIRE
CONNECTORS into opening in back of the
fixture.
7. Properly engage ROMEX PLATE in back
of fixture and tighten screw. Do not over
tighten screw. Make sure that lock washer
is installed under head of screw for proper
grounding.
WAYS TO ELECTRICALLY FEED
UPLED 14", 20" & 30" FIXTURES
Electrical power can be brought to the fixture
using different techniques:
Non-Metallic Cable (NM) using ROMEX
PLATE (provided) and mounted on
fixtures.
Armored Cable (BX) using optional
CONDUIT PLATE and die-cast aluminum
electrical connector (provided loose).
Connections can also be made using
fixture knockouts (14", 22" & 30" units) and
connector supplied loose.
Wiring module accessory ULH-DWM (sold
separately) can be used for forward mount
applications if necessary to allow for
remote supply wiring. Can be used with all
(4) fixture lengths.
Since 9" unit cannot be direct wired, the
ULH-DWM or another UPLED fixture
should be used in conjunction with a
9" unit.
WIRING CONNECTIONS –
UPLED 14", 20" & 30" Fixtures
Non-Metallic Cable (NM)
1. Loosen screw on ROMEX PLATE and
remove.
Wiring methods shown for use with UPLED 14", 20" & 30" fixtures only.