User's Manual

JTECH UHF Desktop Transmitter Installation and Operation Guide 320115K Page 5
Numeric Pager
Numeric pagers can have four ID’s each. The first is used as its unique ID for
single pager paging or as a member of a dynamic group while the second, third,
and fourth ID may be used to enable factory programmed group paging. For
example, pagers 1-20 could be programmed with numbers 1-20 as their first ID.
Pagers 1-10 could also be programmed with ‘factory programmed GROUP 2’ as
their second ID; pagers 11-20 could be programmed with ‘factory programmed
GROUP 3’ as their second ID. This would allow pagers 1-10 to be ‘factory
programmed group paged’ when “*2#*” or “*2*5678#” is entered on the
PeopleAlert keypad or phone and pagers 11-20 to be factory programmed group
paged when “*3#” or “*3*5678#” is entered. For pagers, such as the RapidCall
Numeric, supporting shut down, turn off all pagers by entering “9993#” from the
keyboard.
Glowster Vibe/Flash Pager and CommPass Pagers
The Glowster and CommPass vibe/flash pagers can be programmed with one
primary ID number, which can be used for single pager paging. Glowsters and
CommPass Pagers also respond to the All Call feature.
Range Test
A range test verifies the paging coverage area. Press the * key to get to Range
test screen selecting this option with the # key, or simply enter 9990# from the
keyboard. The Range Test feature sends a Range Test page approximately
every seven (7) seconds to all pagers that have been placed in Group #99. (See
Dynamic Group related instructions in this guide under transmitter operations for
detailed information the group feature.) Range testing is performed by carrying
that pager slowly to the place where the periodic page cannot be received this
establishes the range for transmission. Press any key on the transmitter keypad
to terminate Range Test mode.
Group Paging
The Desktop Transmitter supports group paging, although it is rarely used in
hospitality applications. Two categories of groups exist:
Hardware groups (1-9) are pre-preprogrammed at the factory and call
RapidCall pagers identified within the group with a single transmission
Dynamic groups (1-99; max 10-12 pagers per group) are user-programmable
and call pagers within the groups successively vs. via a single transmission
Groups not available with Glowster or CommPass pagers, as these pagers are
not typically used for staff paging applications where group paging is most used.
Additional details on group paging appear in the transmitter feature section of this
guide or contact your JTECH Account Executive or JTECH Customer Care.