This .pdf document is bookmarked Operating Instructions and Parts Manual Step-Pulley Industrial Drill Presses Models IDP-17 and IDP-22 IDP-22 JET 427 New Sanford Road LaVergne, Tennessee 37086 Ph.: 800-274-6848 www.jettools.com IDP-17 Part No.
ventilated area and work with approved safety equipment, such as face or dust masks that are specifically designed to filter out microscopic particles. 1.0 IMPORTANT SAFETY INSTRUCTIONS 10. Do not operate this machine while tired or under the influence of drugs, alcohol or any medication. READ ALL INSTRUCTIONS BEFORE USING THIS DRILL PRESS. 11. Make certain the switch is in the OFF position before connecting the machine to the power supply. Turn off all controls before unplugging.
25. Maintain tools with care. Follow instructions for lubricating and changing accessories. 30. Secure the drill press to the floor if there is any tendency for it to tip over, walk or slide during operation. 26. Turn off machine and disconnect from power before cleaning. Use a brush or compressed air to remove chips or debris; do not use bare hands. 31. The drill press is intended for industrial use only. 32. Use proper extension cord. Make sure your extension cord is in good condition.
3.0 About this manual This manual is provided by JET, covering the safe operation and maintenance procedures for a JET Model IDP17 and IDP-22 Drill Press. This manual contains instructions on installation, safety precautions, general operating procedures, maintenance instructions and parts breakdown. The drill press has been designed and constructed to provide consistent, long-term operation if used in accordance with the instructions as set forth in this document.
.0 Specifications Model number ........................................................................... IDP-17 ........................................................ IDP-22 Stock number ............................................................................354300 ........................................................ 354301 Motor and electricals: Motor type…………………………………………………….totally enclosed fan cooled, induction, capacitor start......... Horsepower ...........................................
Base and Column: Base size (LxWxH) ................................... 21-3/4 x 13-3/4 x 2-3/16 in. .......................... 22-5/8 x 19-7/16 x 3-3/8 in. ..........................................................................(553 x 350 x 56 mm) .................................... (575 x 494 x 86 mm) Base working surface ............ 16-15/16 x 10-13/16 in. (430 x 275 mm) ............. 21-1/2 x 18-5/16 in. (545 x 465 mm) Base slots, number of ............................................................
6.4.1 Chuck and arbor installation Read and understand the entire contents of this manual before attempting assembly or operation. Failure to comply may cause serious injury. 1. Thoroughly clean arbor (A, Figure 6-2), chuck (B) and spindle (C). Any grease or residue in these areas can cause the pieces to separate and create a safety hazard as well as damage to the tool. 3. Twist chuck to retract chuck jaws if they are exposed. 4.
necessary, do not connect the equipment-grounding conductor to a live terminal. Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the tool's plug. Repair or replace immediately. damaged or worn cord When operated at 115-volt, this tool is intended for use on a circuit that has an outlet that looks like the one illustrated in A, Figure 7-1.
2. Reinstall cover. 3. The plug on end of main power cord must be replaced with a UL/CSA listed plug rated for 230 volt operation. Figure 7-2: voltage conversion 7.3 Extension cords The use of extension cords is discouraged; try to position machines near the power source. If an extension cord is necessary, make sure it is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw.
8.3 Return spring adjustment The return spring is adjusted by the manufacturer and should not require attention. If adjustment is deemed necessary, follow the steps below while referring to Figure 8-3: 1. Unplug machine from power source. 2. Loosen lock nut (E). Do not remove. 3. Firmly hold coil spring cover (F). 4. Pull out cover and rotate until pin (G) on housing engages the next notch in coil spring cover. Turn cover clockwise to decrease tension and counterclockwise to increase tension. 5.
Periodically apply light coat of machine tool oil to quill and column. 11.0 User-maintenance The quill return spring should receive SAE 20 oil once yearly. Apply the oil beneath spring cover (F, Figure 8-3) using a squirt can. Before any intervention on the machine, disconnect it from electrical supply by pulling out plug or turning off main switch at electrical source. Failure to comply may cause serious injury. 11.
.0 Spindle speed charts 12.1 Speed selection for IDP-17 Drill Press Figure 12-1: IDP-17 only 12.
.0 Troubleshooting IDP-17, IDP-22 Symptom Drill press will not start. Drill press does not come up to speed. Drill Press vibrates excessively. Noisy operation. Workpiece burns or smokes. Drill bit wanders. Possible Cause Correction * Drill press unplugged from wall, or motor. Check all plug connections. Fuse blown, or circuit breaker tripped. Replace fuse, or reset circuit breaker. Cord damaged. Replace cord. Starting capacitor bad. Replace starting capacitor.
.0 Replacement Parts Replacement parts are listed on the following pages. To order parts or reach our service department, call 1-800274-6848 Monday through Friday, 8:00 a.m. to 5:00 p.m. CST. Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately. Some parts are shown for reference only, and may not be available individually.
14.1.
14.1.2 IDP-17 Drill Press – Parts List Index No Part No Description Size Qty 1 ................ IDP17-01 ................... Base......................................................................... 550 x 350 x 53 mm ....... 1 201 ............ IDP17-201 ................. Column Assembly (#2, 5) ........................................ ...................................... 1 2 ................ IDP17-02 ................... Column Holder ......................................................... ......
Index No Part No Description Size Qty 51 .............. IDP17-51 ................... Center Pulley ........................................................... ...................................... 1 52 .............. IDP17-52 ................... Pivot Bracket............................................................ ...................................... 1 53 .............. TS-081F031 .............. Head Flat Screw ...................................................... 1/4" x 1/2"....................
14.2.
14.2.2 IDP-22 Drill Press – Parts List Index No Part No Description Size Qty 1 ................ IDP22-01 ................... Base......................................................................... 575 x 500 x 85 .............. 1 201 ............ IDP22-201 ................. Column Assembly (#2,5) ......................................... ...................................... 1 2 ................ IDP22-02 ................... Column Holder ......................................................... ..
Index No Part No Description Size Qty 51 .............. VB-A27 ...................... V-Belt ....................................................................... A27................................ 1 52 .............. IDP22-52 ................... Center Pulley ........................................................... ...................................... 1 53 .............. IDP22-53 ................... Pivot Bracket............................................................ ......................
15.
16.0 Warranty and service JET warrants every product it sells against manufacturers’ defects. If one of our tools needs service or repair, please contact Technical Service by calling 1-800-274-6846, 8AM to 5PM CST, Monday through Friday. Warranty Period The general warranty lasts for the time period specified in the literature included with your product or on the official JET branded website. • JET products carry a limited warranty which varies in duration based upon the product.
This page intentionally left blank.
427 New Sanford Road LaVergne, Tennessee 37086 Phone: 800-274-6848 www.jettools.