Installation Guide

INSTALLATION INSTRUCTIONS
for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)
2
SAFETY & HANDLING
SAFETY
t3FBEBOEGVMMZVOEFSTUBOE"--NBOVGBDUVSFSTJOTUSVDUJPOTCFGPSF
beginning.
t%POPUXPSLBMPOF5XPPSNPSFQFPQMFBSFSFRVJSFE6TFTBGFMJGUJOH
techniques.
t6TFDBVUJPOXIFOIBOEMJOHHMBTT#SPLFOPSDSBDLFEHMBTTDBODBVTF
serious injury.
t8FBSQSPUFDUJWFHFBSFHTBGFUZHMBTTFTHMPWFTFBSQSPUFDUJPOFUD
t0QFSBUFIBOEQPXFSUPPMTTBGFMZBOEGPMMPXNBOVGBDUVSFSTPQFSBUJOH
instructions.
t6TFDBVUJPOXIFOXPSLJOHBUFMFWBUFEIFJHIUT
MATERIALS AND WINDOW HANDLING
t.BLFTVSFPQFSBCMFXJOEPXTBSFMPDLFEQSJPSUPJOTUBMMBUJPO
t)FFENBUFSJBMNBOVGBDUVSFSTIBOEMJOHBOEBQQMJDBUJPOJOTUSVDUJPOT
t1SPUFDUBEIFTJWFTVSGBDFTGSPNEJSUNPJTUVSFEJSFDUTVOMJHIUBOE
folding over onto themselves.
t)BOEMFJOWFSUJDBMQPTJUJPOEPOPUDBSSZýBUPSESBHPOýPPS
t%POPUQVUTUSFTTPOKPJOUTDPSOFSTPSGSBNFT
t4UPSFXJOEPXJOESZXFMMWFOUJMBUFEBSFBJOWFSUJDBMMFBOJOHQPTJUJPO
UPBMMPXBJSDJSDVMBUJPOEPOPUTUBDLIPSJ[POUBMMZ
t1SPUFDUGSPNFYQPTVSFUPEJSFDUTVOMJHIUEVSJOHTUPSBHF
t*OTUBMMPOMZJOUPWFSUJDBMXBMMTBOEXIFODPOEJUJPOTBOETIFBUIJOHBSF
dry.
IF INJURY OCCURS, IMMEDIATELY SEEK MEDICAL ATTENTION!
NEEDED MATERIALS & TOOLS
NEEDED MATERIALS
Note! Follow all material manufacturers’ instructions for proper use
and compatibility.
tHBMWBOJ[FEDBTJOHOBJMTFYUFSJPSUSJNXJOEPXTPS
galvanized roong nails (nailing n windows). Nails must penetrate at
least 1" into wall structure (or as required by local code)
tYTDSFXTGPSXJOEPXTSBUFEBU%1PSBCPWFJODMVEJOHJNQBDU
t(BMWBOJ[FEESJQDBQPSGBDUPSZTVQQMJFE
t4FBMBOU1SPUFDUP8SBQ1SPUFDUP4FBMBOU9-PSFRVJWBMFOU
t1PMZVSFUIBOFMPXFYQBOTJPOGPBN%PX(SFBU4UVGG
TM
Window and
Door or equivalent)
t4IJNToOPUXBUFSEFHSBEBCMFPSDPNQSFTTJCMF
For mulled units or windows without trim or n on the sill:
t.BTPOSZDMJQT
tYTDSFXTGPSGBTUFOJOHNBTPOSZDMJQTUPUIFXJOEPX
tTDSFXTGPSBUUBDIJOHNBTPOSZDMJQTUPTUSVDUVSF4DSFXTNVTU
penetrate at least 1" into framing
For installations into a stud-framed wall:
t+&-%8&/ESBJONBUNBUFSJBMPSFRVJWBMFOU
t+&-%8&/XJEFTFMGBEIFTJWFýBTIJOHPSFRVJWBMFOUGPS
XJOEPXTSBUFEBCPWF%1JGSFRVJSFECZMPDBMDPEF
t4QSBZBEIFTJWFQSJNFS1SPUFDUP8SBQ4BGTFBM4ZTUFNTPSBT
recommended by the self-adhesive ashing manufacturer)
For installations into a buck:
t-JRVJEBQQMJFEýBTIJOH1SPUFDUP8SBQ-8.PSFRVJWBMFOU
TOOLS
t6UJMJUZLOJGF
t+SPMMFS
t)BNNFS
t5BQFNFBTVSF
t$BVMLJOHHVO
t$POTUSVDUJPOTUBQMFSXJUITUBQMFT
t-FWFMhNJOJNVNSFDPNNFOEFE
t%SJMMXJUIUBQFSFECJUBOEDPVOUFSTJOL