Installation Guide
INSTALLATION INSTRUCTIONS
for Pre-Hung Exterior Entry Doors (JII106)
5
PREPARE BUCK
PREPARE STUD-FRAMED WALL
4
5
Sealant joints
Liquid applied
ashing
6. Cut two pieces of
self-adhered ashing
6" wide by the sill
pan width + 3" long.
a. For continuous
slab landings
only, cut out the
insidecorner.
b. Adhere the pieces
of ashing to the
inside corners.
Stretch ashing
as needed to
cover corners and
layat.
7. Smooth gaps or
bubbles beneath
self-adhered ashing
with a J-roller
(remove and replace
if necessary).
8. Seal back corners of
sill pan with sealant.
9. For step-down
landings only, cut
plastic drain screen
to length of sill +
2" and staple 1/2"
below sill edge. The
drain screen provides
a path for air to
dry any incidental
moisture in the
roughopening.
End of Stud-Framed Wall Instructions, continue with section 6,
“INSTALL DOOR.”
FOR RETROFIT INSTALLATIONS
After removing the old door, remove sufcient siding to expose at least
9" of intact building wrap. If damaged, apply new building wrap in a
shiplap manner. Verify header and trimmer studs are structurally sound.
PREPARE BUILDING WRAP
Verify these steps are allowed by the building wrap manufacturer.
1. Trim building
wrap ush with
the edges of the
roughopening.
2. If installing a drip
cap, (recommended
because this
integrates the
building wrap and
drip cap to protect
the structure and
the product from
incidental water)
at the head, slit
building wrap 6"
at 45°. Tape up
asshown.
3. Trim the sides
sufciently to allow
the nailing n to be
mounted against
thesheathing.
4. Apply spray adhesive/
primer to the sill
pan and surrounding area. Follow manufacturer’s instructions for
application methods.
5. Cut a piece of self-adhered ashing the length of the sill and apply
over the sill pan as shown. The bottom of the sill pan should be
completely covered by the self-adhered ashing. For step-down
landings, fold ashing down as shown. For continuous slabs, trim
ush with rough opening.
45˚
6"
Sill pan
width
3"
6"
Discard
(for
continuous
slab only)
Continuous Slab
Landing
Sill pan
width
3"
3"
Sealant
1"
1/2"
Step-Down
Landing
Sill pan
width
3"
3"
Note! This section applies to installations into a buck only. For
installations into a stud-framed wall, begin with section 5, “PREPARE
STUD-FRAMED WALL.”
1. Seal any joint larger than 1/16" in the buck and between the buck
and the concrete/masonry with sealant.
2. Cover the buck and the surrounding concrete/masonry at the head
and jambs and sill with liquid applied ashing as shown.
END of Buck Instructions, SKIP to section 6, “INSTALL DOOR.”