Instructions / Assembly
INSTALLATION INSTRUCTIONS
for Pre-Hung Exterior Entry Doors (JII106)
2
FULLY SHEATHED WALL CONSTRUCTION
The wall framing is
covered by sheathing
and the door will be
mounted with the
exterior trim ush
against the sheathing.
This installation
assumes building wrap
is properly installed
prior to installation.
OPEN-STUD CONSTRUCTION
The wall framing needs to be completely surrounded by backing
support (non water-degradable, thin (max. 1/8" thick) sheet material
such as plywood or lauan) before installing building wrap and the
door. The door will be mounted with the exterior trim ush against the
applied backing support.
This installation guide specically addresses masonry/block wall,
sheathed wall and open-stud construction.
MASONRY/BLOCK WALL CONSTRUCTION
This installation
assumes that a
building professional
has already properly
fastened and sealed
a framework of studs
(often called a buck)
to the concrete/
masonry wall.
ROUGH OPENINGS
Buck
Trimmer
studs
Header
Sheathing
Sill area
King
stud
PROVIDED MATERIALS
•2-#9x21/2"screws
•Foamweatherstripwedges(cornersealpads)
NEEDED MATERIALS
Note! Follow all material manufacturers’ instructions for proper use
and compatibility. When using ashing, spray adhesive/primer, sealant
and foam products, we recommend using the same manufacturer and
verifying compatibility.
•Lockset
•10dgalvanizedcasingnails(ifplantostain)or#8x3"deckscrews(if
plan to paint)
•Non-compressibleorwaterdegradableshims
•Pre-formedsillpanorsheetmetalashing/bendablevinylsheeting
for sill pan
•Sealant(polyurethaneifpainted,100%siliconeifleftexposed)and
backer rod
MATERIALS AND TOOLS
•Polyurethane low expansion foam (Dow Great Stuff™ Window and
Door or equivalent)
•Plasticdrainscreenwithcrisscrossorwovenpattern(soldin6"widths
to protect rain gutters) for step-down landings
•3/8"staplesforstep-downlandings
•Drip capifrequiredbecauseofdoorlocationandexposure.Doors
with an adequate overhang (see our Appropriate Protection
document at www.jeld-wen.com/learn/resources/care-maintenance)
may not need a drip cap.
For installations into a Buck:
Liquidappliedashing(ProtectoWrapLWM200orequivalent)
For installations into a stud-framed wall:
4"to6"wideself-adhesiveashingandcompatibleprimerifrequired
(9"ifrequiredbylocalcode)
SAFETY AND HANDLING
SAFETY
•ReadandfullyunderstandALLmanufacturers’instructionsbefore
beginning. Failure to follow proper installation and nishing
instructions may result in the denial of warranty claims for
operational performance problems.
•Donotworkalone.Twoormorepeoplearerequired.Usesafelifting
techniques.
•Usecautionwhenhandlingglass.Brokenorcrackedglasscancause
serious injury.
•Wearprotectivegear(e.g.safetyglasses,gloves,earprotection,etc.).
•Operatehand/powertoolssafelyandfollowmanufacturer’soperating
instructions.
•Usecautionwhenworkingatelevatedheights.
MATERIALS AND DOOR HANDLING
•Makesuretheoperatingpanelissecuredpriortoinstallation.
•Heedmaterialmanufacturer’shandlingandapplicationinstructions.
•Protectadhesivesurfacesfromdirt,moisture,directsunlightand
folding over onto themselves.
•Handleinverticalposition;donotdragonoor.
•Donotputstressonjoints,cornersorframes.
•Storedoorindry,well-ventilatedareainvertical,leaningpositionto
allowaircirculation;donotstackhorizontally.
•Protectfromexposuretodirectsunlightduringstorage.
•Installonlyintoverticalwallsandwhenconditionsandsheathingare
dry.
IF INJURY OCCURS, IMMEDIATELY SEEK MEDICAL ATTENTION!