Instructions / Assembly

INSTALLATION INSTRUCTIONS
for Pre-Hung Exterior Entry Doors (JII106)
5
5. Cuttwopiecesof
JELD-WEN self-
adhesive ashing 6"
wide by the sill pan
width+3"long.
a. For continuous
slab landings
only, cut out the
inside corner.
b. Adhere the
pieces of
ashing to the
inside corners.
Stretch ashing
as needed to
cover corners
and lay at.
6. Smooth gaps or
bubbles beneath
self-adhesive
ashing with a
J-roller (remove
and replace if
necessary).
7. Sealbackcornersof
sill pan with sealant.
8. For step-down
landings only, cut
plastic drain screen
to length of sill +
2"andstaple1/2"
below sill edge. The
drain screen provides a path for air to dry any incidental moisture in
the rough opening.
End of Stud-Framed Wall Instructions, continue with section 7,
“INSTALL DOOR.”
FOR RETROFIT INSTALLATIONS
After removing the old door, remove sufcient siding to expose at least
9"ofintactbuildingwrap.Ifdamaged,applynewbuildingwrapina
shiplap manner. Verify header and trimmer studs are structurally sound.
PREPARE BUILDING WRAP
Verifythesestepsdonotvoidthebuildingwrapmanufacturer’s
warranty.
1. Trim building wrap
ush with the
edges of the rough
opening.
2. Atthehead,slit
building wrap 6"
at45°.Tapeupas
shown.
3. Applyspray
adhesive/primer
to the sill pan
and surrounding
area. Follow
manufacturer’s
instructions
for application
methods.
4. Cutapieceof
JELD-WEN self-
adhesive ashing
the length of the sill
and apply over the
sill pan as shown.
The bottom of
the sill pan should
be completely
covered by the self-adhesive ashing. For step down landings, fold
ashing down as shown. For continuous slabs, trim ush with rough
opening.
6
PREPARE STUD - FRAMED WALL
45˚
6"
Sill pan
width
3"
6"
Discard
(for
continuous
slab only)
Continuous Slab
Landing
Sill pan
width
3"
3"
Sealant
1"
1/2"
Step-Down
Landing
Sill pan
width
3"
3"
5
PREPAREBUCK
Note! This section applies to installations into a buck only. For
installations into a stud-framed wall, begin with section 6, “PREPARE
STUD-FRAMED WALL.”
1. Seal any joint larger than 1/16" in the buck and between the buck
and the concrete/masonry with sealant.
2.Coverthebuckandthesurroundingconcrete/masonryatthehead
and jambs and sill with liquid applied ashing as shown.
3.Applydiamondlathtoallashedsurfacestobecoveredbystucco.
END of Buck Instructions, SKIP to section 7, “INSTALL DOOR.”
Sealant joints
Diamond lath
Liquid applied
ashing