User's Manual

- 18 - UDEE / UDRE - 332170A revision02Fr En De PRELIMINARY
T
Red stop palmswitch
unlocked,
UDEE transmitter
powered up
Green "On/Horn"
button pressed
Passive stop if "Dead Man"
duration is exceeded (1)
or
Battery pack is
disconnected/discharged (2)
or
Electronic key removed from
UDE transmitter in operation
OFF
Standby
Active
3 states
of UDEE
UDRE receiver RS1 and
RS2 safety relays
UDEE transmitter
green indicator light
3 states of red
indicator light of UDEE
(battery pack charge
state)
Active stop by pressing
stop palmswitch button
Or
Last action on
function pushbutton
(1) "Dead Man" duration
Passive stop : battery pack is discharged
UTILISATION
(2)
Battery pack charge > 90 %
90% > Battery pack charge > 10%
Battery pack charge < 10%
90% > Charge > 10 % Charge < 10 %
Charge < 10 %
3.4- Functioning block diagram