by Air Specialties INSTALLATION INSTRUCTIONS SA-50D SA-70D SA-90S SA-90SL SA-150S SA-200S SA-90SLM j.tantay 10.07.09 AIR SPECIALTIES LTD. SA-90SM Toll Free: 1.866.890.6457 1.800.810.
READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION 1. Do not install this fan where air temperature may exceed 40 C (104 F). 2. The electric service supply voltage must be 120V/60HZ. 3. Do not kink or excessively bend the electrical wires. 4. Follow all the appropriate codes, i.e. local electrical and safety codes, the National Electrical Codes (NEC) and the Occupation Safety And Health Act (OSHA) . 5.
MODEL SA-90SL / SLM ACCESSORIES a) 1 pc. Light Grille b) 1 pc. Light Unit Fan/Light Grille Fan/Light Motion Sensor Grille SA-90SL SA-90SLM c) 2 pcs. Fluorescent Bulb, 2 pins, 13W WARNING: Bulb contains Mercury, dispose it according to local, state & federal laws and regulations. (Model: 13WPL) MODEL SA-90SM Motion Sensor a) 1 pc. Grille with Motion Sensor These Ceiling Mount Ventilating Fan Models Utilizes: Mounting Height 8.
LIGHT UNIT BLACK WHITE C) SA-90SL JUNCTION BOX Ballast 1 WIRING DIAGRAM: (cont.) WHITE Ballast 2 TO SWITCH BLACK TO NEUTRAL BLACK CAPACITOR FAN MOTOR WHITE GREEN TO SWITCH TO NEUTRAL TO GROUND FAN HOUSING INSTALLATION A) Wooden Joist Installation Fig. 1 - Install fan housing between ceiling joists using sufficient length of screws as shown in Fig. 1 with the fan O/L facing the desired exhaust duct direction. - Install fan mounting brackets as shown in Fig.