Installation Guide
10
Leading the Way
IVC US Residential Installation Guide – Sheet Vinyl Flooring
double layer construction. Porous wood underlayments must be primed.
- Any failure of the underlayment or ooring due to the underlayment is NOT the
responsibility of IVC US. IVC US does not recommend installing resilient ooring
over wood ooring or suboors applied directly over concrete or sleeper-
construction oors.
• Concrete — See Grade Levels below:
Grade Levels
Suspended: An acceptable suspended oor is a concrete or wood substrate with a
minimum of 18” (460mm) of well-ventilated air space beneath it. IVC US recom-
mends that a moisture vapor barrier be placed on the ground below the air space.
On-Grade: An acceptable on-grade oor is a concrete substrate in direct surface
contact with the ground at the surrounding ground level. The concrete
slab should be protected from moisture penetration and incorporate a
proven moisture vapor barrier.
Below-Grade: An acceptable below-grade oor is a concrete substrate partially or
completely in contact with the ground below the average surrounding ground level.
The concrete slab should be protected from moisture penetration and incorporate a
proven moisture vapor barrier.
• VCT (well bonded, on and above grade)
• Ceramic (well bonded)
• Terrazzo (well bonded)
• Self-leveling and patching compounds (latex fortied Portland cement based only)
• Resilient oor (no more than 2 layers, well bonded, non-cushioned – residential
applications only)
• Radiant heat oors (not exceeding 85°F (29°C) and approved by the manufacturer for the
use of their product with resilient vinyl ooring applications)
• OSB (underlayment grade)
OSB underlayment panels must be underlayment grade as specied and warranted by
the manufacturer. Underlayment panels and joints must be fastened and reinforced
according to manufacturer’s instructions. Completely sand the oor with a oor sander,
so that the oor is smooth and at. Note: The chips in OSB overlap. Without sanding
properly, OSB has high and low spots throughout the oor that could telegraph through
the vinyl.
- Surface must be primed using IVC FLEX-PRIM Acrylic Latex Primer.
• Particle board (underlayment grade)
Particle board underlayment panels must be underlayment grade as specied and war-
ranted by the manufacturer.
- Surface must be primed using IVC FLEX-PRIM Acrylic Latex Primer.
Unacceptable Surfaces:
• Inter-ex and any perimeter bonded products • Carpet
• Any oating oor system • Cork
• Resilient tile installed below grade • Cushion-back vinyl
This document is reviewed on an ongoing basis. Control # MKF_0012_0 8/13/13