Crimping Instructions
Formed (Stamped) Crimp
Contacts
Assembly Instructions:
1. Strip wires to length. For wire strip lengths,
see page 67.
2. Open the hand tool and place the contact
in the chosen die, ensuring that the locating
plate is positioned between the collar and
crimp saddle. Then squeeze tool gently to
hold the contact in place.
3. Insert the wire.
4. Cycle the tool.
5. Remove the wire and inspect the crimp.
The strands should be visible at both ends of
the crimp. There should be no loose strands
(see Figures 1-3). The contact should be co-linear
with the wire (see Figure 4). Bent contacts
are unacceptable (see Figure 5).
Crimping Instructions
Machined Crimp Contacts
Assembly Instructions:
1. Strip wires to length. For wire strip
lengths, see page 69.
2. Attach the correct locator (turret) to
the hand tool.
Contact Type Locator Color
Pin Blue
Socket Green
Earthing Black
3. Adjust the dial for the wire gauge.
4. Place the contact into the locator and
insert the wire into the contact as indicat-
ed on the locator (turret) label.
Figure 6 - Correct
Notes:
Wire Insulation.
Wire Strands.
Contact.
Inspection Window.
Strands must be visible.
Figure 7 - Unacceptable
5. Cycle the tool.
6. Remove and inspect the contact.
Strands should be visible through the
inspection window (see Figure 6). There
should be no loose strands (see Figure 7).
Figure 4 - Correct
Figure 1 - Correct
Figure 5 - Unacceptable
Side View
Side View
Front View
Front View
Figure 2 - Unacceptable
Figure 3 - Unacceptable
1
2
3
4
Assembly Instructions