Service Guide

Technical Reference
Intel® Server System SC5650HCBRP Service Guide 79
System Environmental Specification
Table 10. Environmental Specification
Temperature
Non-operating: -40 ° to 70 °C
Operating: 10 ° to 35 °C; derated 0.5 °C for every 1000 ft. (305 m) to a maximum of
10,000 feet
Humidity
Non-operating: 90% relative humidity (non-condensing) at 30 °C.
Shock
Operating: 2.0 g, 11 msec, 1/2 sine
Packaged: Operational after an 18-inch free fall.
Acoustic Noise
Base, BRP, and LX configurations - 5.8 BA LWA idle; 6.0 BA LWA typical operating
Electrostatic Discharge
(ESD)
Tested to 15 kilovolts (kV); no component damage
Current Usage
Calculation Power Usage
The total combined wattage for your configuration must be less than the wattage rating for your power supply.
Use the two worksheets in this section to calculate the total used by your configuration. For current and voltage
requirements of add-in boards and peripherals, see your vendor documents.
Worksheet, Calculating DC Power Usage
Table 11. Power Usage Worksheet
Current (maximum) at voltage level
Device +3.3 V +5 V -5 V +12 V -12 V 5 V Standby
Baseboard, Front Panel
Board and Fans
Processor(s)
Memory
3.5-inch Diskette Drive
CD-ROM Drive
Second 5.25-inch Device
Third 5.25-inch Device
1st Hard Drive
2nd Hard Drive
3rd Hard Drive
4th Hard Drive
5th Hard Drive