User manual

ENGLISH
Quick Installation Guide
IMON
www.insys-icom.com
These short operating instructions apply for the following devices of INSYS icom:
IMON-G100
IMON-G200
IMON-U300
IMON-U310
www.insys-icom.com/manual
It is intended for a quick commissioning by the operator. Refer to the associated manual for further information.
This and other associated manuals can be found on our website in the menu Support and Downloads >
Documentation. Scan the QR code above or enter the URL into your web browser.
Defects liability terms
A use other than the intended use, an ignorance of the safety instructions and the documentation, the use of insufficiently qualified
personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resulting from this. The liability of the
manufacturer ceases to exist.
Intended Use
The product may only be used for the purposes specified in the function overview of the manual. In addition, it may be used for the
following purposes:
Usage and mounting in an industrial cabinet.
Switching and data transmission functions in machines according to the machine directive 2006/42/EC.
Usage as data transmission device, e.g. for a PLC.
The product may not be used for the following purposes and used or operated under the following conditions:
Use, control, switching and data transmission in machines or systems in explosive atmospheres.
Controlling, switching and data transmission of machines, which may involve risks to life and limb due to their functions or when a
breakdown occurs.
Technical Boundaries
Max. line length for antennas, power supplies, inputs and outputs as well as other signals: 30 m
Max. line length of serial connection lines: 3 m
Cable cross-section: 0.25 … 2.5 mm², flexible lines require end sleeves
Support
If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e-mail
under support@insys-tec.de.
Technical Data
The product is only intended for the use within the permissible technical limits specified in the data sheets. These limits must be observed.
Operating voltage
12 V … 24 V DC (±20%)
GSM/GPRS frequencies (2G)
Power consumption
typ. 1.0 W, max. 3.0 W
UMTS/HSPA frequencies (3G)
Level inputs
HIGH level = 3 ... 12 V
LOW level = 0 ... 1 V
Contact open condition: HIGH
Real-time clock (RTC) buffer time
Current consumption input at
LOW potential
max. 0.5 mA when
connecting to GND
Temperature range
Digital output (changeover
relay), max. switch voltage
30 V (AC/DC)
Maximum permissible humidity
Digital output (changeover
relay), max. current load
1 A (DC) / 0.5 A (AC)
(resistive load)
IP rating