User's Manual
— 8 —
PRIOR TO OPERATION
1. Power source
Ensure that the power source to be utilized conforms
to the power source requirements specified on the
product nameplate.
2. Power switch
Ensure that the knob of the pressure switch is in the
“OFF” position (Fig. 2). If the plug is connected to a
receptacle while the knob is in the “ON” position, the
compressor will start operating immediately and can
cause serious injury.
EC 10SB(SL) EC 12
Fig. 2
3. Extension cord
When the work area is far away from the power
source, use an extension cord of sufficient thickness
and rated capacity (refer page 6). The extension cord
should be kept as short as practicable.
WARNING: Damaged cord must be replaced or
repaired.
SPECIFICATIONS
Model EC10SB(SL) EC12
Motor Single-Phase, Induction Motor
Power Source Single-Phase, 240V AC 50Hz
Input
2 HP
(1.5 KW)
Current 9.5 A
Tank Capacity
4 gal.
(15.1 ltr)
Maximum Pressure
116 PSI 125 PSI
(8 bar) (8.6 bar)
at 40 PSI 6.3 CFM 5.9 CFM
(2.8 bar) (177 ltr/min) (168 ltr/min)
at 90 PSI 5.1 CFM 4.8 CFM
(6.2 bar) (144 ltr/min) (136 ltr/min)
at 100 PSI 4.6 CFM 4.6 CFM
(6.9 bar)
(130 ltr/min) (130 ltr/min)
Lubrication Oil-less Oil
ACCESSORY
WARNING:Accessory other than these shown
below can lead to malfunction and
resulting injuries.
STANDARD ACCESSORY
EC 10SB(SL)
NO ACCESSORIES
EC 12
Dipstick - - - - - - - - - - - - - - 1
APPLICATIONS
䡬 Air source of the pneumatic nailer and stapler.
WARNING: Never use compressor for
applications other than compressor
for pneumatic nailer and stapler.
Free Air
Delivery
Knob of the pressure switch
ON
OFF
OFF
ON