INSTRUCTION MANUAL AND SAFETY INSTRUCTIONS FOR AIR COMPRESSOR MODEL EC 10SB (SL) EC 10SB(SL) EC 12 EC 12 WARNING Improper and unsafe use of this compressor can result in death or serious bodily injury! This manual contains important information about product safety. Please read and understand this manual before operating the compressor. Please keep this manual available for others before they use the compressor.
—CONTENTS— Page IMPORTANT INFORMATION ............................... 2 MEANINGS OF SIGNAL WORDS ........................ 2 SAFETY IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE COMPRESSOR ........ 3 REPLACEMENT PARTS ........................................ 5 GROUNDING INSTRUCTIONS ............................ 5 EXTENSION CORD ............................................... 6 Page OPERATION AND MAINTENANCE NAME OF PARTS .................................................. 7 SPECIFICATIONS ....................
SAFETY IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE COMPRESSOR WARNING: Death or serious bodily injury could result from improper or unsafe use of compressor. To avoid these risks, follow these basic safety instructions: READ ALL INSTRUCTIONS 1. NEVER TOUCH MOVING PARTS. Never place your hands, fingers or other body parts near the compressor’s moving parts. Never insert your fingers or other objects into the housing's ventilator. Such an action invites the danger of injuries or electric shocks. 2.
16. CHECK DAMAGED PARTS AND AIR LEAK. Before further use of the compressor, a guard or other part is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, air leak, and any other conditions that may affect its operation.
33. THE SAFETY VALVE MUST WORK PROPERLY. Risk of bursting. Before starting the compressor pull the ring on the safety valve to make sure the valve moves freely. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion. REPLACEMENT PARTS When servicing use only identical replacement parts. Repairs should be conducted only by a Hitachi authorized service center.
EXTENSION CORD Use only three-wire extension cords that have three-prong grounding-type plugs and three-pole receptacles that accept the compressor’s plug. Replace or repair damaged cord. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating.
OPERATION AND MAINTENANCE NOTE: The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the compressor. Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own compressor.
SPECIFICATIONS Model EC10SB(SL) Motor EC12 Single-Phase, Induction Motor Power Source Single-Phase, 240V AC 50Hz 2 HP (1.5 KW) Input Current 9.5 A 4 gal. (15.1 ltr) Tank Capacity 116 PSI (8 bar) 125 PSI (8.6 bar) at 40 PSI (2.8 bar) 6.3 CFM (177 ltr/min) 5.9 CFM (168 ltr/min) at 90 PSI (6.2 bar) 5.1 CFM (144 ltr/min) 4.8 CFM (136 ltr/min) at 100 PSI (6.9 bar) 4.6 CFM (130 ltr/min) 4.
6. Right running position 4. Confirm the power receptacle If the power receptacle only loosely accepts the plug, the receptacle must be repaired. Contact the nearest electric store for repair service. If such a faulty receptacle is used, may cause overheating, resulting in a serious hazard. Position the compressor on a flat surface , in a well ventilated area away from atmospheric agents and not in explosive areas. TRANSPORT 5.
Knob of the pressure switch MAINTENANCE WARNING: Disconnect the compressor from the power source and remove the compressed air from the air tank before performing the maintenance operations. Allow the compressor to cool before performing the maintenance operations. Knob of the pressure reducer 1. Cleaning the intake filter Pressure gauge (A) indicates the pressure in the air tank Pressure gauge (B) indicates the working pressure Remove the intake filter (Refer to Fig.
Drain cap Fig. 8 Pour oil into the hole of the dipstick. To the level indicated on the dipstick (Refer to Fig. 4). For oil replacement, follow the table below. OIL TYPE SAE 5W50 SYNTHETIC OIL (–20°+120°F) For both summer and winter use SAE 10W40 MULTI-GRADED OIL (+50°+120°F) For warm weather use only (2) Check the oil level of the pumping element every 50 hours or once a week. (3) Change the oil every 300 working hours or every 6 months.
— 12 —
EC10SB(SL) Item No. 1 Code No. 881-455 Joint Part Name 2 Q’ty Reference No.
— 14 —
EC12 Item Item No. 1 Code No. 881-450 Screw 2 881-554 Intake filter 1 881-553 Filtering element 1 881-453 Filter plate 1 3 4 5 Part Name Q’ty Reference No. 1 7012010000 No. 56 Code No. 7210430000 57 882-606 Pressure gauge 2 7110240000 7210010000 58 881-511 Joint 1 7081090000 7458340000 59 881-504 Blocking nut 1 7023040000 1 7084190000 60 881-505 Joint 1 7081140000 Joint 1 7085180000 7021010000 881-510 Part Name Pressure reducer Q’ty Reference No.
— 16 —
— 17 —
Hitachi Koki Co., Ltd. 312 Code No.