WATER DRAINAGE
Certain functions of your air conditioning unit create condensation and the unit
may need to evacuate accumulated water. Please carefully follow these instruc-
tions according to your operating and usage conditions.
COOLING MODE
During cooling mode, the unit attempts to evacuate all of the moisture through
the exhaust hose to the outside along with the warm air exhaust. At times, when
the humidity level is very high, excess water may collect in the bottom tray. If the
water level of the bottom tray reaches a predetermined level, the unit beeps 8
times, the digital display area shows error P1 . At this time the air conditioning/
dehumidification process will immediately stop, even though the fan motor may
continue running (this is normal).
Carefully move the unit to a drain location, remove the bottom drain plug and let
the water drain away (see Figure E). Reinstall the bottom drain plug and restart
the machine until the P1 symbol disappears. If the error repeats, call for service.
NOTE: Be sure to reinstall the bottom drain plug before using the unit.
DEHUMIDIFYING MODE ONLY
Remove the upper drain plug from the back of the unit and simply attach the drain hose to the hole. Place the
open end of the hose adapter directly over the drain area in your floor or into another receptacle (see Figure F).
NOTE: Make sure the hose is secure so there are no leaks. Direct the hose toward a drain that is located lower
than the unit, making sure that there are no kinks that will stop water flow. Place the end of the hose into the
drain and make sure the end of the hose is down to let the water flow smoothly (see Figure F). Do not li up the
hose as this may cause water to flow back into the unit.
WINDOW SLIDER KIT INSTALLATION
Your window slider kit has been designed to fit most standard double-hung and slider windows, However, it may
be necessary for you to improvise/modify some aspects of the installation procedures for certain types of win-
dows. Please refer to Figure G & Figure H for minimum and maximum window openings. The window slider kit
can be fixed with an included security peg (see Figure I).
INSTALLATION IN A DOUBLE-HUNG SASH WINDOW:
Continuous
drain hose
Fig. F
Fig. E
√
Remove upper
drain plug
Window filler panel
Minimum: 2’ 1/8” (67.5cm)
Maximum: 4’ (123cm)
Fig. G
Standard
Double-hung
Window
Horizontal
Slider
Window
Fig. H
Window filler panel
Minimum: 2’ 1/8” (67.5cm)
Maximum: 4’ (123cm)
Fig. I
Window
filler panel
Security Peg