EN COOKERS MAJESTIC CONVERSION KIT INSTALLATION INSTRUCTIONS cod.
CHANGING THE INJECTORS WARNING "This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit.
CONVERSION KIT INSTALLATION INSTRUCTIONS Table 3 CONVERSION KIT INSTALLATION INSTRUCTIONS CODE NATURAL GAS 120 PROPANE GAS 145 75 90 UM30D(N/W/Q/QN)(E3) 145 190+75 120 90 120+44 75 145 145 145 90 190+75 120 190 120+44 90 90 UM096D(N/W/Q/QN)E3 UMD106D(N/W/Q/QN)E3 UM096D(N/W/Q/QN)S3 UMD106D(N/W/Q/QN)S3 117 75 145 145 90 90 90 190+75 120 120 120+44 75 75 145 UM09FD(N/W/Q/QN)E3 UMD10FD(N/W/Q/QN)E3 UM09FD(N/W/Q/QN)S3 UMD10FD(N/W/Q/QN)S3 145 145 145 92 90 90 UM09PD(N/W/Q/QN)
BURNERS OF THE TOP - Replacement of the injectors Procedure: SR - R - P • small solid top burner • Remove the grill and the burners from the hob. • Bruciatori SR – R – P : SR – R – P burners: unscrew injectors “U” using a 7 mm spanner (fig. 1) and replace them with those for the newgas according to table number 2 on page 20. Save the orifices removed from the appliance for future use. Procedure: DCC • DCC – Dual burners: unscrew the 2 screws “P” and remove cover “C” fig.2.
ADJUSTING THE MINIMUM GAS FLOW When installing the cooker you must check that the minimum gas flow of the burners on is correctly regulated. If the type of gas is changed it is indispensable to adjust the minimum flow. The adjustment procedure is as follows. Burners on the hob (fig. 13) 1. Light one burner at a time and turn the flame up to maximum 2. Remove the knob of the corresponding gas tap and insert screwdriver in the screw as shown in figure 14a or 14b (DUAL). 3. Turn the tap to minimum position. 4.
IGNITION OF THE “DUAL” BURNER off maximum minimum index lighting ADJUSTMENT OF THE PRESSURE REGULATOR FOR USE WITH DIFFERENT TYPE OF GAS The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with Natural Gas at a nominal outlet pressure of 5”w.c. or Propane at a nominal outlet pressure of 10”w.c.
CORRECT RELATIONSHIP BETWEEN THE IGNITER AND THE MAIN BURNER UM30D (N/W/Q/QN)(E3) UM096D (N/W/Q/QN)(E3) UMD106D (N/W/Q/QN)(E3) 6
CORRECT RELATIONSHIP BETWEEN THE IGNITER AND THE MAIN BURNER UM09FD (N/W/Q/QN)(E3) UMD10FD (N/W/Q/QN)(E3) UM09PD (N/W/Q/QN)(E3) 7
CORRECT RELATIONSHIP BETWEEN THE IGNITER AND THE MAIN BURNER UM127D (N/W/Q/QN)(E3) UM128D (N/W/Q/QN)(E3) 8
CORRECT RELATIONSHIP BETWEEN THE IGNITER AND THE MAIN BURNER UM159D (N/W/Q/QN)(E3) INJECTORS FOR THE APPLIACE INSTALLED AT AN ALTITUDE EXCEEDING 2000 ft INJECTORS FOR THE APPLIANCE INSTALLED AT AN ALTITUDE EXCEEDING 2000 ft BURNER GAS ORIFICE SIZE (1/100) mm SR NATURAL (A) 117 R NATURAL (A) 141 P NATURAL (A) 141 DCC NATURAL (A) 185 DUAL NATURAL (A) 74+185 DUAL (only AUX) NATURAL (A) 74 SR LP (E) 74 R LP (E) 87 P LP (E) 88 DCC LP (E) 112 DUAL LP (E) 42+117 DUAL (only AU
INSTRUCTIONS TO AFFIX THE CONVERSION KIT LABEL area for affixing the conversion plate area for identification label of the service agency making the conversion 10