Use and Care for Majestic II

18
ADJUSTING THE MINIMUM GAS FLOW
SERVICE & MAINTENANCE INSTRUCTIONS
When installing the cooker you must check that the minimum gas ow of the burners on is correctly regulated. If the
type of gas is changed it is indispensable to adjust the minimum ow. The regulating procedure is as follows.
A) Burners on the hob (g. 13)
1. Light one burner at a time and turn the ame up to maximum.
2. Remove the knob of the corresponding gas tap and insert screwdriver in the screw as shown in gure 14a or
14b (DUAL).
3. Turn the tap to minimum position.
4. Unscrew, turning to the left, to increase the ame, or screw to the right to decrease it.
5. If a liquid gas is used (Butane - Propane), the regulating screw must be fully screwed in.
Replacement Parts.
Authorized replacement parts may be used in performing service on the appliance. Replacement parts are avai-
lable from factory authorized part distributors.
Service and maintenance only to be carried out by an authorised person.
To replace parts such burners, valves and electric components, the hotplate must be removed from the bench top
by releasing the attachment hooks, loosening the attachment screws of each burner, unscrewing the hotplate at-
tachments nuts which are visible at the bottom of the surface, removing the hotplate top and  nally replacing the
defective parts.
Note: if the valves must be replaced,  rst disassemble the ignitions switches wires.
It is recommended to replace the valve gaskets each time the valve is replaced.
WARNING: after rst installation of the appliance, after gas conversion kit installation or after any service intervention
concerning main gas parts of the appliance , make the leak test using water with soap on the gas connections in
order to verify the correct installation. Do not use re for gas leak testing. The test is valid if there is no bubble or foam
build-up during a period of one minute.
NON WORKING APPLIANCES
Before calling the After Sales Service, check that the appliance is connected or that the main switch is activated.
After, call the After Sales Service. The faults must be checked by a skillfull technician.
Remark: the appliance is equipped with a safety thermostat, adjusted at a certain temperature. In case it reaches
a higher temperature, the appliance switches off
By-pass
r egula-
ting
Figure 14b (DUAL)
AUX AUX
Figure 1 3 Figure 14a