Report No.: 17PNS11103 01001 Safety Data Sheets Name of Goods: Polymer Li-ion Battery Commissioner: Dongguan Sunly Battery Technology Co., Ltd. GUANGDONG UTL CO.
Page 3 of 22 Report No.: 17PNS11103 01001 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Product Identifier Product name: Polymer Li-ion Battery Model: SL601122 3.8V, 120mAh, 0.
Page 4 of 22 Report No.: 17PNS11103 01001 GHS Label elements, including precautionary statements Emergency Overview Signal word Danger Hazard Statements Causes severe skin burns and eye damage May cause an allergic skin reaction May cause cancer Causes damage to organs through prolonged or repeated exposure This product is an article which contains a chemical substance. Safety information is given for exposure to the article as sold.
Page 5 of 22 Report No.: 17PNS11103 01001 If skin irritation or rash occurs: Get medical advice/attention Inhalation IF INHALED: Remove victim to fresh air and keep at rest in position comfortable for breathing Immediately call a POISON CENTER or doctor/physician Ingestion IF SEALLOWED: Rinse mouth.
Page 6 of 22 Report No.: 17PNS11103 01001 3. COMPOSITION/INFORMATION ON INGREDIENTS Common Chemical Name Chemical Formula Concentration (%) CAS Number Lithium Cobalt Oxide LiCoO2 41.3 12190-79-3 Carbon black C 1.0 1333-86-4 Graphite powder C24X12 21.0 7782-42-5 Polyvinylidene fluoride (C2H2F2)n 1.0 24937-79-9 Aluminum foil Al 5.9 7429-90-5 Carboxymethyl cellulose -- 0.29 9004-32-4 Styrene-butadiene rubber (C8H8.C4H6)x 0.54 9003-55-8 Copper Cu 10.
Page 7 of 22 Report No.: 17PNS11103 01001 minutes. Keep eye wide open while rinsing. Do not rub affected area. Remove contact lenses, if present and easy to do. Seek immediate medical attention/advice. Skin Contact Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. May cause an allergic skin reaction. Seek immediate medical attention/advice. Inhalation Remove to fresh air. If breathing has stopped, give artificial respiration.
Page 8 of 22 Report No.: 17PNS11103 01001 Suitable Extinguishing Media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Unsuitable extinguishing media CAUTION: Use of water spray when fighting fire may be inefficient. Specific Hazards Arising from the Chemical The product causes burns of eyes, skin and mucous membranes. Thermal decomposition can lead to release of irritating gases and vapors. Product is or contains a sensitizer.
Page 9 of 22 Report No.: 17PNS11103 01001 Methods for Containment Prevent further leakage or spillage if safe to do so. Methods for Cleaning up Pick up and transfer to properly labelled containers. 7. HANDLING AND STORAGE Precautions for safe handling Handling In case of rupture: Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. In case of insufficient ventilation,wear suitable respiratory equipment.
Page 10 of 22 Report No.: 17PNS11103 01001 o n TWA: 2.5 mg/m 3 F Phosphate(1-), hexafluoro, lithium 21324-40-3 TWA: 2.5 mg/m 3 F TWA: 2.5 mg/m 3 dust (vacated)TWA: 2.5 mg/m 3 3 3 Copper TWA: 0.2 mg/m fume TWA:0.1 mg/m fume 7440-50-8 TWA: 1 mg/m 3 dust and mist TWA: 1 mg/m 3 dust and mist (vacated)TWA: 0.
Page 11 of 22 Skin and Body protection Report No.: 17PNS11103 01001 Wear protection gloves and protective clothing. Long sleeved clothing. Chemical resistant apron. Impervious gloves. Respiratory protection If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approved respiratory protection should be worn. Positive-pressure supplied air respirators may be required for high airborne contaminant concentrations.
Page 12 of 22 Report No.
Page 13 of 22 Report No.: 17PNS11103 01001 11. TOXICOLOGICAL INFORMATION Information on likely routed of exposure Product Information Product does not present an acute toxicity hazard based on known or supplied information. In case of rupture Inhalation Specific test data for the substance or mixture is not available. Corrosive by inhalation. (based on components). Inhalation of corrosive fumes/gases may cause coughing, choking, headache, dizziness, and weakness for several hours.
Page 14 of 22 Report No.: 17PNS11103 01001 Information on toxicological effects Symptoms Erythema (skin redness). Burning. May cause blindness. Coughing and/ wheezing. Itching. Rashes. Hives Delayed and immediate effects as well as chronic effects from short and long-term exposure Sensitization May cause sensitization by skin contact. Mutagenic Effects No information available. Carinogenicity The table below indicates whether each agency has listed any ingredient as a carcinogen.
Page 15 of 22 Report No.: 17PNS11103 01001 (29 CFR 1910. 1200), this product has been determined to cause systemic target organ toxicity from chronic or repeated exposure. (STOT RE). STOT – repeated exposure Chronic Toxicity Chronic exposure to corrosive fumes/gases may cause erosion of the teeth followed by jaw necrosis. Bronchial irritation with chronic cough and frequent attacks of pneumonia are common. Gastrointestinal disturbances may also be seen. Contains a known or suspected carcinogen.
Page 16 of 22 Report No.: 17PNS11103 01001 Copper 7440-50-8 96h EC50: 0.0310.054mg/L (Pseudokirchneriella subcapitata) 72h EC50: 0.0426-0.0535 mg/L (Pseudokirchneriella subcapitata) 96h LC50: 0.00680.0156 mg/L (Pmephales promelas) 96h LC50:=1.25 mg/L (Lepomis macrochirus) 96h LC50:=0.052 mg/L (Oncorthynchus mykiss) 96h LC50:=0.2mg/L(pim ephales promelas) 96h LC50:<0.3 mg/L(pimephales promelas) 96h LC50:=0.112mg/L(pi mephales promelas) 96h LC50:=0.112 mg/L(poecilia reticulate) 96h LC50:=0.
Page 17 of 22 Report No.: 17PNS11103 01001 material is a hazardous waste. Consult the appropriate state, regional, or local regulations for additional requirements Contaminated Packaging Dispose of contents/containers in accordance with local regulations.
Page 18 of 22 Emergency Response Guide Number 147 TDG Not regulated MEX Not regulated ICAO Not regulated IATA Not regulated Proper Shipping Name NOT REGULATED Hazard Class N/A IMDG/IMO Report No.: 17PNS11103 01001 Not regulated Hazard Class N/A EmS-No. F-A, S-I RID Not regulated ADR Not regulated ADN Not regulated 15.
Page 19 of 22 Chemical name Report No.: 17PNS11103 01001 CAS No Weight-% SARA 313-Threashold Values % 12190-79-3 30-60 0.1 Copper – 7440-50-8 7440-50-8 7-13 1.0 Aluminum – 7429-90-5 7429-90-5 5-10 1.0 Nickel – 7440-02-0 7440-02-0 1-5 0.
Page 20 of 22 Report No.: 17PNS11103 01001 California Proposition 65 This product contains the following Propositions 65 chemicals Chemical name California Proposition 65 Carbon black – 1333-86-4 Carcinogen Nickel – 7440-02-0 Carcinogen U.S.
Page 21 of 22 Report No.: 17PNS11103 01001 Canada WHMIS Hazard Class Non-controlled 16. OTHER INFORMATION NFPA Health Hazards 1 Flammability 0 Instability 0 NFPA Health Hazards 1 Flammability 0 Instability 0 Physical and Chemical HazardsPhysical and HMIS Health Hazards 0 Flammability 0 Instability 0 Personal Protection X Prepared By Product Stewardship 23 British American Blvd.
Page 22 of 22 Report No.: 17PNS11103 01001 Photos Fig.1 Overall view I of battery Fig.2 Overall view II of battery GUANGDONG UTL CO., LTD. Lianding Testing Building, No.18 Center Road of Yayuan Industrial Zone, Nancheng Disctrict, Dongguan, Guangdong, China Tel:+86-769-3893 3228 Fax:+86-769-3893 3229 E-mail: sales@gdutl.