Datasheet

www.apem-idec.eu ww.apem-idec.eu
D-061 D-062
Enabling Switch Features
Compliant with international standards 3-position enabling switches
By holding an enabling switch, an operator can avert danger when a machine operates unexpectedly.
When the panicked operator either releases or grasps tightly the enabling switch, the switch disables the
machine operation in either situations.
In IDEC’s enabling switches, both actuators and contacts are duplicated. When a hazard must be
stopped at high safety level, disparity of two contacts must be detected using safety relay module so
that failures such as damage or welding of contacts and actuators can be detected.
As for usability, the operating force required to shift the switch from position 2 to 3 is the same when the
button is pressed on the center or off-center. Operating force does not increase even when pressed off-
center by one finger. High durability is also provided; operating force hardly changes after 10000
operations.
Terminal
Contact
Movable
Contact
Position 1
General Pushbutton Switch
(2-position)
3-position Enabling Switch
OFF
OFF
ON
OFF
ON
No position
1. Press
1. Press
lightly
3. Press
fully
4. Release
2. Release
2. Release
Button
released
Position 2
Button
pressed
Position 3
Button
pressed
fully
0
0
5
10
15
20
25
30
35
40
45
50
2135
467
Center pressed
Off-center pressed
Stroke (mm)
Operating Force (N)
Off-center Center
HE2B-M2
JAPAN
NC1
0
0
1
NC2
NO1 NO211 12 21 22C1 C2
Enabling Contact Enabling Contact
Enabling Contact Enabling Contact
Enabling Contact Enabling Contact
Position 1 (Contacts OFF)
Position 2 (Contacts ON)
Position 3 (Contacts OFF)
Actuator
Actuator
Ergonomically-designed OFF-ON-OFF 3-position operation
Duplicated actuators and contacts