Electrical system overview
17
19
18
1
16
15
14
13
3
2
12
11
10
4
5
6
8
9
7
1. Auger rotation sensor
2.
Switch for tilting the collector
3. Seat safety switch
4. Hour meter
5. Switch for the lever for the auger servicing position
6. Headlights
7. Microswitch, parking brake
8. Sensor for cutting deck in place
9. Safety switch for the lift lever
10. Relay
11. Fuses
12. Battery
13. Buzzer
14. Auger control switch with LED indicators
15. Power outlet (12 V)
16. Ignition lock
17. Collector position sensor
18. Switch for collector hatch
19. Sensor for collector full
Seat safety switch
The seat safety switch starts the safety circuit when the
operator lifts from the seat. The engine and the drive to
the blades stop if the blades are engaged or the parking
brake is not applied. See also
Safety circuit on page
9
.
Hour meter
The hour meter shows how many hours the engine has
run. The time with ignition on but engine off is not
registered. The last digit shows tenths of an hour (6
minutes).
Battery
The battery is a rechargeable lithium iron phosphate
battery, LiFePO
4
. If the voltage in the battery is too low,
it goes into protection mode and does not react when
you turn the ignition on. When the battery is in protection
mode or if it is too weak to start the engine, it must be
charged. See
To charge the battery on page 24
.
Power outlet
The voltage of the power outlet is 12 V. The power outlet
is fused, see
To replace a fuse on page 24
.