Operating Instructions EMAX designs and manufactures products for safe operation. However, operators and maintenance persons are responsible for maintaining safety. All safety precautions are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in operation. Keep these instructions for reference. Silent Air Portable Air Compressor Model # : HP01P006SS UPC: 815002013992 EMAX Compressor 1000 Cass Dr., Clayton, OH 45315 USA 866.294.
HULK Power Air Compressors Contents Model Specifications…………………………… 2 Installing the air filter …………………… 8 Description………………………………………… 3 Operation …………………………………………… 9 Get to know your compressor…………… 3 Before operating your new air compressor: …………………………………… 9 Safety Information……………………………… 4 General Overview………………………………… 9 Basic Guidelines………………………………… 5 Installation and Location………………… 9 Breathable Air………………………………… 5 Connecting to Power Source…………… 9 Pressurized Components………………… 5 Extension
Silent Air Series Description 7 9 6 5 10 8 11 fig 1 3 2 1 12 4. SAFETY VALVE The safety valve automatically relieves pressure from the air tank in the event of excessive pressure build up. Safety Valve is preset at factory. Do not attempt to make any adjustments to the safety valve. Periodically pull the ring on the safety valve end to check that it is working properly. 5.RESERVOIR AIR PRESSURE GAUGE Indicates pressure of compressed air built up in the tank. 6.
HULK Power Air Compressors Safety Information off. When lever is moved down to the "Auto" position, the pressure switch is engaged and will start the compressor pump automatically when tank pressure is below the factory-set minimum. The pressure switch continues to monitor the pressure and turns the pump off when the pressure reaches the factory-set maximum. This manual contains very important information to know and understand. This is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS.
Silent Air Series Basic Guidelines 5. If the air tank develops a leak, replace it immediately. Never repair, weld or make modifications to the air tank or its attachments. 1. Allow only trained, authorized persons who have read and understood these operating instructions to use this compressor. Failure to follow the instructions, procedures and safety precautions in this manual can result in accidents and injuries. 2. NEVER start or operate the compressor under unsafe conditions.
HULK Power Air Compressors cm) of clearance. 10. Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators. There is an increased risk of electric shock if your body is grounded. 3. Use shims to level compressor if installation area is not flat. This will avoid excessive vibration and premature pump wear. 11. To reduce the risk of electrical shock or injury, do not expose tool to moisture. Don’t use this tool in damp or wet locations. Keep out of rain.
Silent Air Series substances are spilled, clean up immediately. 19. The air pressure switch is set at the factory for optimum performance of your equipment. Never attempt to bypass or remove this switch as serious damage to equipment or personal injury could result from excessive air pressure. 8. When checking or when refilling air line antiicer systems with antifreeze compound, shut off compressor and allow it to cool.
HULK Power Air Compressors 9. D o not use the tool if the switch does not turn it on and off. Any tool that cannot be controlled with the switch is dangerous and must be repaired. used (C, fig 1) it must be attached to the metal screw of the receptacle. The use of an adaptor plug is illegal in some areas, including Canada. Check your local codes. If you have any doubts or if the supplied plug does not correspond to your electrical outlet, consult a qualified electrician before proceeding. 10.
Silent Air Series extension cord and a longer air hose, choose the latter. It is far better for the life of the compressor. If necessary, care must be taken in selecting an extension cord appropriate for use with your specific air compressor. ●● Use a heavy-gauge extension, since very thin or very long cord may cause voltage drop and result in loss of power in the compressor and overheating.
HULK Power Air Compressors Drain Valve 1. Make sure the drainage valve (fig 5) is closed and not in the open position. Adjusting the air pressure Your air compressor is supplied with an air pressure regulator. This regulator adjusts the air pressure supplied to the hose. fig 5 fig 7 Pressure Switch 5 8 • To increase air pressure, turn air regulator knob (fig 2.10) clockwise. • To decrease air pressure, turn air regulator knob counterclockwise. • Use the outlet pressure gauge (fig 7.
Silent Air Series 7. Protect electrical cord and air hoses from damage (such as being stepped on or driven over). Wrap all cords and hoses loosely around the (cooled) air compressor. 8. Place air compressor in a cool, dry, safe, and indoor location. Monthly ●● Inspect air system for leaks by applying soapy water to all joints. Tighten these joints if leaks are discovered. Storage When storing your compressor: 1. Be sure the unit is turned OFF. 2. Unplug it from power source. 3.
HULK Power Air Compressors Trouble Possible Cause Corrective Action Compressor runs noisily and metallic sounds are heard Compressor will not come to max pressure Head gasket or reed valve damaged. Stop the compressor and contact customer support Compressor doesn’t provide as much air as when new and/or cuts off after a much shorter time period. 1. Tank has reduced capacity due 1. Open drain valve to release water to water retention 2. Pressure switch is out of adjust- 2.
Silent Air Series Schematic Drawing 41 42 40 16 17 15 14 18 19 20 21 22 13 12 11 10 23 73 54 43 9 30 31 24 25 26 27 28 29 32 33 8 7 6 34 53 45 52 5 4 3 35 36 61 60 62 2 50 1 51 44 49 46 55 47 57 56 63 48 64 37 39 58 59 72 65 71 72 66 69 67 68 13 HP01P006SS man v.
HULK Power Air Compressors Warranty Statement HULK makes every effort to ensure that this product meets high quality and durability standards. HULK warrants to the original retail consumer a 2-year limited warranty as of the date the product was purchased at retail and that each product is free from defects in materials. Warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence or accidents, repairs or alterations and lack of maintenance.