Operating Instructions EMAX designs and manufactures products for safe operation. However, operators and maintenance persons are responsible for maintaining safety. All safety precautions are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in operation. Keep these instructions for reference. Stationary Air Compressor Model # : HI05V08Y1 / HS05V08Y1 UPC: 815002014265 / 815002014272 EMAX Compressor 1000 Cass Dr., Clayton, OH 45315 USA 866.
HULK Power READ INSTRUCTION MANUAL BEFORE OPERATING. In order to receive maximum performance and long life from your compressor, the following instructions should be read carefully and all points regarding installation and operation of the unit should be noted and observed. Carefully reading this manual before connecting anything to the motor or compressor is necessary for optimum trouble-free operation.
Stationary Air Compressor Inspection ●●Inspect compressor prior to any use. ●●Check for external damage that might have occurred during transit. Check for possible damage from transit and test the pulley by turning it freely with your hands. Be careful of moving parts. ●●Report any damage to delivery carrier immediately. Do not operate unit if damaged during shipping, handling or use. Damage may result in bursting and cause injury or property damage.
HULK Power of excessive pressure build up. The safety valve is preset at factory. Do not attempt to make any adjustments to the safety valve. Periodically pull the ring on the safety valve end to check that it is working properly. 5.RESERVOIR AIR PRESSURE GAUGE Indicates pressure of compressed air built up in the tank. 6.PRESSURE SWITCH Turns the air compressor on and off and will start the compressor pump automatically when tank pressure is below the factory-set minimum.
Stationary Air Compressor In the event the compressor is used for the purpose of breathing air application and proper in-line safety and alarm equipment is not simultaneously used, existing warranties are void, and EMAX Air Force Technology disclaims any liability whatsoever for any loss, personal injury or damage. CALIFORNIA PROPOSITION 65 This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
HULK Power safety glasses. Everyday eyeglasses are NOT safety glasses. Dust mask, non-skid safety shoes, hard hat, or hearing protection should be used in appropriate conditions. Electrical Safety Be sure only trained and authorized personnel maintain this compressor in accordance with all applicable federal, state and local codes, standards and regulations. Follow all NEC (National Electric Code) standards especially those concerning equipment grounding conductors. 2. W ear proper apparel.
Stationary Air Compressor 13. Always disconnect the tool from power source before making any adjustments, storing, servicing, or changing accessories. Such preventative safety measures reduce the risk of starting the tool accidentally. 14. Keep away from flammables. Do not attempt to operate this tool near flammable materials or combustibles. Failure to comply may cause serious injury or death. Keep all persons away from the discharge opening of hoses or tools or other points of compressed air discharge.
HULK Power 2. Make sure all hose connections are adequately secured to prevent tools or hose ends from being accidentally disconnected. current (AC) power source. If connected to a circuit protected by fuses, use time-delay fuse marked “D”. Installation should be executed by a licensed electrician who should verify the ACTUAL VOLTAGE of the circuit into which the tool will be connected and that it is properly grounded. 3. Remove adjusting keys or wrenches before turning the tool on.
Stationary Air Compressor check that all pipes and hoses are firmly connected. ●●Do not use the air compressor if any damage is found. If damaged, have an authorized service center inspect and test the air compressor to ensure that is working properly. ●●Pull the ring on the safety valve before each use to make sure the valve is functional.
HULK Power Starting ●●Check oil level before starting. The oil should be in the center of the sight glass. Oil level should be to center of red circle in sight glass while in the OFF position soapy water to all joints in the air transport piping. Tighten these joints if bubbles form. Adjusting the air pressure Use an air pressure regulator (not supplied). This regulator adjusts the air pressure supplied to the piping system.
Stationary Air Compressor Daily ●●Before each use, 1. check for any unusual noise or vibration. 2. be sure all nuts and bolts are tight. ●●After each use, drain condensation from the air tank. Weekly ●●Inspect air filters (fig.6) weekly and clean or change as needed. Troubleshooting Always inspect the compressor before use, and make sure it is in good working condition. Make sure all air vents are clear. Check the power cable to make sure it is intact and free from cracks, bare wires etc.
HULK Power Overheating Storage Compression of air generates heat, much of which is dissipated as air passes over the intercooler and/or after cooler. Overheating can be caused by: 1. Pump running backwards (reverse direction). Proper rotation is counter-clockwise when facing the flywheel. 2. One or more head valves are failing to seat properly. 3. Blown cylinder head gasket. Restriction in head, intercooler, or check valve. 4. Lack of oil (check oil level). 5.
Stationary Air Compressor Troubleshooting Chart Trouble Compressor will not start Possible Cause Corrective Action 1. Blown fuse or circuit breaker tripped 1. Replace or reset fuse/circuit breaker 2. Loose electrical connections 2. Check wiring connnections 1. Restricted air filter 1. Replace air filter 2. Defective check valve 2. Replace check valve 3. Air leak in safety valve 3. Check valve by pulling on ring.
HULK Power Hulk Warranty Statement Hulk Power by EMAX Compressor makes the following Warranty guarantee: ●● Standard warranty: That each compressor unit is free from defects in material, workmanship, and parts for 1 year from the date of purchase. Hulk Power by EMAX is not reasonable for downtime during warranty service. If downtime is necessary, it is the purchaser’s discretion and obligation, at purchases expense, to have a redundant compressor.