MSA 2060 Benchmark Performance Results
The performance figures provided here are for reference as many variables exist between array configurations, workloads, drive
types, disk group setup parameters and host system setup.
Hewlett Packard Enterprise has traditionally published a set of end-to-end MSA performance specifications that are fed into HPE
Sizer tools which are based on conservative real-world configurations. For consistency, the MSA performance numbers have been
documented in both Benchmark and End-to-End Performance tables. These numbers are subject to change without notice
HPE MSA 2060 Benchmark Performance Results
Benchmark Performance Results
1
HPE MSA 2060 (with SSDs)
IOPS
Random Reads
2
325,000
Random Writes
3
175,000
Sequential
4
Segmented Sequential Reads
5
13.1 GB/s
Segmented Sequential Writes
6
7.3 GB/s
Notes:
-
1
Performance results were generated using internal HPE test tools. Number and type of applications, drive type and number
of drives, operating system used, and the number of hosts will affect overall performance. This table is provided strictly as a
test-lab comparison.
-
2
Dual controller configuration, four SSDs, RAID 1, two SSDs per disk group; one disk groups per pool, four volumes per pool,
block size: 8k, 16Gb FC direct connect to array.
-
3
Dual controller configuration, 20 SSDs, RAID 10, ten SSDs per disk group; one disk groups per pool, four volumes per pool,
block size: 8k, 16Gb FC direct connect to array.
-
4
Sequential performance numbers were generated using segmented sequential workloads. For segmented sequential
workloads with a queue depth greater than 1, each sequential stream is targeted to operate on a separate LBA range. Other
types of sequential workloads that target specific LBA ranges may achieve higher results.
-
5
Dual controller configuration, 20 SSDs, RAID 10, ten SSDs per disk group, 1 disk group per pool, four volumes per pool,
256k block size, 16Gb FC direct connect to array.
-
6
Dual controller configuration, 18 SSDs, RAID 5, nine SSDs per disk group, 1 disk group per pool, four volumes per pool, 256k
block size, 16Gb FC direct connect to array.