HPE ProLiant DL20 Gen10 Server
Technical Specifications
Page 35
500W/800W Redundant Power Supply
Input Requirements
(per power supply)
Rated Line Voltage
100 to 120 VAC
200 to 240 VAC
BTU Rating
Maximum
For 800W Power Supply: 3207 BTU/hr (at 100 VAC), 3071 BTU/hr (at 200 VAC), 3112 BTU/hr (at 240 VDC) for China
Only
For 500W Power Supply: 1979 BTU/hr (at 100 VAC), 1911 BTU/hr (at 200 VAC), 1965 BTU/hr (at 240 VDC) for China
Only
Power Supply Output
(per power supply)
Rated Steady-State Power
For 800W Power Supply: 800W (at 100 VAC), 800W (at 240 VAC), 800W (at 240 VDC) input for China only
For 500W Power Supply: 500W (at 100 VAC), 500W (at 240 VAC), 500W (at 240 VDC) input for China only
Maximum Peak Power
For 800W Power Supply: 800W (at 100 VAC), 800W (at 240 VAC), 800W (at 240 VDC) input for China only
For 500W Power Supply: 500W (at 100 VAC), 500W (at 240 VAC), 500W (at 240 VDC) input for China only
For 800W Power Supply: 800W (at 100 VAC), 800W (at 240 VAC), 800W (at 240 VDC) input for China only
System Inlet Temperature
Standard Operating Support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above
sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20°C/hr (36°F/hr).
The upper limit and rate of change may be limited by the type and number of options installed.
System performance during standard operating support may be reduced if operating above 30°C (86°F).
Extended Ambient Operating Support
For approved hardware configurations, the supported system inlet range is to be: 5° to 10°C (41° to 50°F) and 35° to 40°C
(95° to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m
(2953 ft) to a maximum of 3050 m (10,000 ft). The approved hardware configurations for this system are listed at the
URL:http://www.hpe.com/servers/ashrae
For approved hardware configurations, the supported system inlet range is to be: 40° to 45°C (104° to 113°F) at sea level
with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m (2953 ft) to a maximum of 3050
m (10,000 ft).
The approved hardware configurations for this system are listed at the URL: http://www.hpe.com/servers/ashrae
System performance may be reduced if operating in the ambient operating range.
Non-operating
-30°C to 60°C (-22°F to 140°F) Maximum rate of change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
8% to 90% - Relative humidity (Rh), 28°C maximum wet bulb temperature, non-condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing.