ProLiant DL160 Gen10 Server

QuickSpecs
HPE ProLiant DL160 Gen10 Server
Technical Specifications
Page 22
Relative Humidity
Operating
8% to 90% - Relative humidity (Rh), 28°C maximum wet bulb temperature,
non-condensing.
(non-condensing)
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb
temperature, non-condensing..
Altitude
Operating
3050 m (10,000 ft). This value may be limited by the type and number of
options installed. Maximum allowable altitude change rate is 457 m/min
(1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander
position A
-
Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient
environment. Noise emissions were measured in accordance with
ISO 7779 (ECMA 74) and declared
in accordance with ISO 9296 (ECMA 109). The listed sound levels apply to standard shipping
configurations. Additional options may result in increased sound levels. Please have your HPE
representative provide information from the HPE EMESC website for further technical details
regarding the configurations listed below.
Configuration SKU
LFF Config
SFF Config
Idle
LWAd
4.5 B
4.5 B
LpAm
28.1 dBA
27.8 dBA
Operating
LWAd
5.1 B
5.1 B
LpAm
34.0 dBA
33.0 dBA
NOTE:
Acoustics levels will vary depending on system configuration. Values are based on below
configurations and are for reference only.
NOTE:
Additional options may result in increased sound levels.
NOTE:
Product conformance to cited product specifications is based on sample (type) testing,
evaluation, or assessment. This product or family of products is eligible to bear the appropriate
compliance logos and statements.
NOTE:
LFF configuration included one Intel SKL-SP Xeon-
B 3104 processor, two HP 4TB SATA
7.2K LFF HDD, two 8GB PC4
-2666V-R, three system fans and one 500W 12V no AUX Pwr Sply.
NOTE:
SFF configuration included one Intel SKL-SP Xeon-
S 4108 processor, two HP 500GB 6G
SATA 7.2K SFF HDD, two 16GB
PC4-2666V-
R, three system fans, one 1U 500W 12V HTPLG RED
HE
-P-A, one Smart Array E208i-a SR Gen10 Ctrlr.
Emissions Classification (EMC) Regulatory Information
To view the regulatory information for your product, view the Safety and Compliance Information for Server, Storage, Power,
Networking, and Rack Products, available at the Hewlett Packard Enterprise Support Center:
http://www.hpe.com/support/Safety-Compliance-EnterpriseProducts