CAUTION: To prevent damage to electrical components, properly ground the server before
beginning any installation procedure. Improper grounding can cause electrostatic discharge.
2. Back up all server data.
3. Power down the server (Powering down the server on page 30).
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Do one of the following:
a. Extend the server from the rack (Extend the server from the rack on page 30).
b. Remove the server from the rack (Remove the server from the rack on page 31).
6. Remove the access panel (Remove the access panel on page 31).
7. If installed, remove the low profile riser cage.
8. Install the secondary full-height PCI riser cage (Installing a secondary full-height PCI riser cage
option on page 86).
9. Remove the existing rear guide bracket from the card, if installed.
10. If installing a 3/4-length GPU, install the bracket supplied in the kit.
A T-15 Torx screwdriver is required to install the bracket.
Hardware options installation 95