HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
- About this Guide
- 1- Planning a Subsystem
- Defining Subsystems
- What is Failover Mode?
- Selecting a Cache Mode
- Enabling Mirrored Caching
- What is the Command Console LUN?
- Determining Connections
- Assigning Unit Numbers
- What is Selective Storage Presentation?
- 2- Planning Storage Configurations
- Where to Start
- Determining Storage Requirements
- Configuration Rules for the Controller
- Addressing Conventions for Device PTL
- Choosing a Container Type
- Creating a Storageset Profile
- Planning Considerations for Storageset
- Changing Characteristics through Switches
- Specifying Storageset and Partition Switches
- Specifying Initialization Switches
- Specifying Unit Switches
- Creating Storage Maps
- 3- Preparing the Host System
- Installing RAID Array Storage System
- Making a Physical Connection
- Preparing LUNs for Access by Tru64 UNIX FileSystem
- DECsafe Available Server Environment (ASE)
- HSG80 Units and Tru64 UNIX Utilities
- Solution Software Upgrade Procedures
- New Features, ACS 8.7 for Tru64
- 4- Installing and Configuring HSG Agent
- 5- FC Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring Storage Containers
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Verifying Storage Configuration from Host
- 6- Using CLI for Configuration
- 7- Backing Up, Cloning, and Moving Data
- A- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- B- Installing, Configuring, and Removing the Client
- C- SWCC Agent in TruCluster Environment
- SWCC Overview
- Running the SWCC Agent on a V4.0G Cluster
- Running the SWCC Agent under ASE Services
- Running the SWCC Agent on a V5.x Cluster
- Problems with Running the Agent on Multiple Clusters
- Configure the Controller
- Use Multiple-Bus Failover Mode
- Verify That the HSG80/HSG60 Unit Offsets Are Zero
- Install and Run the Agent on One Cluster Member
- Example of Installing the Agent on a Cluster Member
- Create the CAA Action Script
- Create the CAA Resource
- Glossary
- Index
Index
HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
Index–3
fabric topology 5–26
devices
changing switches
fabric topology
5–25
configuration
fabric topology
5–16
creating a profile
2–16
disk drives
adding
fabric topology
5–23
adding to the spareset
fabric topology
5–24
array
2–15
corresponding storagesets
2–34
dividing
2–26
removing from the spareset
fabric topology
5–24
disklabel
creating partitions on a LUN
3–7
displaying the current switches
fabric topology
5–26
dividing storagesets
2–26
E
enabling
switches
2–28
erasing metadata
2–33
establishing a local connection
5–2
F
fabric topology
configuration
single controller cabling
5–3
failover
1–5
multiple-bus
1–7
transparent
1–5
file
Tru64 UNIX utility
3–10
filesystem
creating on a LUN
3–8
mounting
3–8
preparing LUNs
3–6
First enclosure of multiple-enclosure subsystem
storage map template 1
A–4, A–7, A–9,
A–11, A–14, A–16, A–19
functions
Agent
4–1
G
genvmunix, using 3–9
geometry
initialize switches
2–33
Geometry parameters
2–33
H
Host access
restricting in multiple-bus failover mode
disabling access paths
1–24
host access
restricting by offsets
multiple-bus failover
1–26
transparent failover
1–23
restricting in multiple-bust failover mode
1–24
restricting in transparent failover mode
1–21
disabling access paths
1–23
separate links
1–22
host adapter
installation
3–6
preparation
3–6
host connections
1–13
naming
1–13
Host storage configuration
verify
5–27
HSG Agent
install and configure
4–1
network connection
4–3
overview
4–2
reconfigure agent
4–10
remove agent
4–13
I
initialize switches
changing
fabric topology
5–26
CHUNKSIZE