HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
- About this Guide
- 1- Planning a Subsystem
- Defining Subsystems
- What is Failover Mode?
- Selecting a Cache Mode
- Enabling Mirrored Caching
- What is the Command Console LUN?
- Determining Connections
- Assigning Unit Numbers
- What is Selective Storage Presentation?
- 2- Planning Storage Configurations
- Where to Start
- Determining Storage Requirements
- Configuration Rules for the Controller
- Addressing Conventions for Device PTL
- Choosing a Container Type
- Creating a Storageset Profile
- Planning Considerations for Storageset
- Changing Characteristics through Switches
- Specifying Storageset and Partition Switches
- Specifying Initialization Switches
- Specifying Unit Switches
- Creating Storage Maps
- 3- Preparing the Host System
- Installing RAID Array Storage System
- Making a Physical Connection
- Preparing LUNs for Access by Tru64 UNIX FileSystem
- DECsafe Available Server Environment (ASE)
- HSG80 Units and Tru64 UNIX Utilities
- Solution Software Upgrade Procedures
- New Features, ACS 8.7 for Tru64
- 4- Installing and Configuring HSG Agent
- 5- FC Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring Storage Containers
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Verifying Storage Configuration from Host
- 6- Using CLI for Configuration
- 7- Backing Up, Cloning, and Moving Data
- A- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- B- Installing, Configuring, and Removing the Client
- C- SWCC Agent in TruCluster Environment
- SWCC Overview
- Running the SWCC Agent on a V4.0G Cluster
- Running the SWCC Agent under ASE Services
- Running the SWCC Agent on a V5.x Cluster
- Problems with Running the Agent on Multiple Clusters
- Configure the Controller
- Use Multiple-Bus Failover Mode
- Verify That the HSG80/HSG60 Unit Offsets Are Zero
- Install and Run the Agent on One Cluster Member
- Example of Installing the Agent on a Cluster Member
- Create the CAA Action Script
- Create the CAA Resource
- Glossary
- Index
SWCC Agent in TruCluster Environment
C–15HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
C–15
Problems with Running the Agent on Multiple Clusters
Running the agent on multiple cluster members can cause problems in operational
ease-of-use. For example, if you make changes with the agent on one cluster member,
those changes are not immediately reflected by the agents on other cluster members,
so what you see in the Navigation Window might not be what you expect. Running the
agent on multiple cluster members is not harmful, but it can be confusing, depending
on your configuration.
The required ACS firmware version for the controller implements a locking
mechanism that prohibits data corruption caused by simultaneous system access,
either from cluster members or standalone systems. Your data integrity is protected.
The following is recommended for running SWCC in a TruCluster Server
environment. The controller recommendations are specific to the HSG80, HSG60, and
HSZ80 controllers:
• Configure your hardware as described in the TruCluster Server Hardware
Configuration manual.
• Use multiple-bus failover mode so that all units are available to both ports of an
HSG80/HSG60/HSZ80 controller.
• Set the HSG80/HSG60 unit offset to 0 for all connections.
• Set the HSG80/HSG60/HSZ80 access path so that the appropriate cluster member
connections are enabled.
• Make sure that the HSG80/HSG60/HSZ80 Command Console LUN (CCL) is
enabled. We recommend that you use the controller in SCSI-3 mode so that the
CCL is always located at LUN0.
• If you use selective storage presentation (SSP) on the HSG80/HSG60 controller,
or zoning on a Fibre Channel switch, remember that this selective view of your
storage is reflected in the Navigation Window.
• Install the SWCC agent on one cluster member. (The SWCC installation script
does not allow you to install it on more than one member at a time.)
• Edit the /sbin/init.d/swcc startup script to probe for a TruCluster Server
environment.
• Use the cluster application availability (CAA) scripts described in this procedure