Software User Manual

Performance Control XP user guide 57
Operands
userid
Specifies the user ID for the SVP.
If the user ID includes any non-alphanumeric character, the user ID must be enclosed by double
quotation marks (").
NOTE: Be sure to specify a user ID that should be used exclusively with the Export Tool. For
detailed information, see ”Requirements for using the Export Tool” on page 44.
password
Specifies the password of the user.
If the password includes any non-alphanumeric character, the password ID must be enclosed by double
quotation marks (").
Example
This example logs the user expusr into the SVP whose IP address is 158.214.127.170. The password
is pswd.
The show subcommand
Syntax
show
Description
The show subcommand outputs the following information to the standard output (for example, to the
command prompt):
The period during which monitoring data was collected onto the SVP (storing period).
The interval at which the monitoring data was collected (gathering interval).
Auto LUN XP collects statistics by the two types of storing periods: in short range and in long range. In
short-range monitoring, the monitoring data between 1 and 15 days is stored in the SVP, and in
long-range monitoring, the monitoring data up to three months is stored in the SVP.
The show subcommand displays the storing period and the gathering interval for these two types of
monitoring data: in short range and in long range.
For example, the show command outputs the following information:
Short Range indicates the storing period and gathering interval of the monitoring data stored in short
range. Long Range indicates those of the monitoring data stored in long range. When you run the
Export Tool, you can export the monitoring data within these periods into files. If you use the shortrange
or longrange subcommand additionally, you can narrow the term of data to be exported (see ”The
shortrange subcommand” on page 68 or ”The longrange subcommand” on page 71).
From indicates the starting time for collecting monitoring data. To indicates the ending time for collecting
monitoring data.
Interval indicates the interval at which the monitoring data was collected (gathering interval. For
example, Interval : 15 min. indicates that monitoring data was collected at 15-minute intervals.
svpip 158.214.127.170
login expuser pswd
Short Range From: 2004/10/01 01:00 - To: 2004/10/01 15:00Interval : 1min
Long Range From: 2004/09/01 00:00 - To: 2004/10/01 15:00Interval : 15min
Remote Copy From: 2004/09/30 00:00 - To: 2004/10/01 15:00